IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 1962;1:513-521.)
© 1962 by The Association for Research in Vision and Ophthalmology, Inc.

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by SCHWARTZ, B.
Right arrow Articles by FELLER, M. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by SCHWARTZ, B.
Right arrow Articles by FELLER, M. R.

Temperature Gradients in the Rabbit Eye

BERNARD SCHWARTZ 1 and MARTIN R. FELLER 2

1 Division of Ophthalmology, Department of Surgery, State University of New York, Downstate Medical Center, Brooklyn, N. Y.
2 Division of Ophthalmology, Department of Surgery, State University of New York, Downstate Medical Center, Brooklyn, N. Y.; National Council to Combat Blindness, Inc., New York, N. Y.

Measurements of the temperature of the various parts of the rabbit eye under both local and general Nembutal anesthesia were made ivith the thermistor as the temperature-measuring device at a room temperature of 22 to 24° C, and a relative humidity of 33 to 53 per cent. The equipment and its calibration are described in detail. The existence of a temperature difference of 6° C. (corrected for the depressant effect of Nembutal anesthesia on rectal temperature) was shown to exist between the orbit and the central corneal surface along the pupillary axis. No significant difference was noted between right and left eyes except for the central corneal surface temperature under local Ophthaine anesthesia, when the temperature of the left eye was found to be higher than that of the right by 0.5° C. An estimation of the temperature gradients indicates that at the mid-lens position the gradient increases sharply toward the corneal surface. Some of the possible physiologic effects of the ocular temperature gradient are discussed, such as the choice of temperature for study of the metabolism of ocular tissues in vitro, the role of the temperature gradient in the maintenance of the intraocular pressure on the basis of the irreversible thermodynamic approach, and its role in the transfer of fluid across the cornea.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1962 by the Association for Research in Vision and Ophthalmology