IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 1971;10:800-809.)
© 1971 by The Association for Research in Vision and Ophthalmology, Inc.

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by TITTEL, P. G.
Right arrow Articles by RICHARDS, R. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by TITTEL, P. G.
Right arrow Articles by RICHARDS, R. D.

Distensibility Measurements of the Rabbit Eye

P. G. TITTEL 1 and R. D. RICHARDS 1

1 Department of Ophthalmology, University of Maryland School of Medicine, Baltimore, Md. 21201

Distensibility measurements were made on the eyes of living and dead rabbits in situ and on freshly enucleated rabbit eyes. Twelve rabbits were used for the experiment. In the enucleated eyes distensibility measures were made around the anteroposterior plane and the equator, while only equatorial measurements were monitored on the living and dead eye in situ. From the measurements on the enucleated eyes in the anteroposterior plane, the ratio of cornea to sclera distensibility was obtained. The equatorial (scleral) measurements produced no appreciable difference in distensibility of the three states as the pressure was raised to 50 mm. Hg. Above this level an increase in distensibility was noticeable in the enucleated eye. In all three states distensibility was greatest at 30 mm. Hg, falling off at 50 mm. Hg and reaching a steady value at approximately 90 mm. Hg. The cornea to sclera ratio at these pressure levels were 1:0.76, 1:0.7, and 1:1, respectively.

Key Words: distensibility • volume changes • circumference gauge • electrical resistance • intraocular pressure • steady state • ocular rigidity • rabbits

Submitted on February 5, 1971