IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by O'Neal, M. R.
Right arrow Articles by Sarver, M. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by O'Neal, M. R.
Right arrow Articles by Sarver, M. D.

Investigative Ophthalmology & Visual Science, Vol 25, 837-842, Copyright © 1984 by Association for Research in Vision and Ophthalmology


ARTICLES AND REPORTS

Corneal response to rigid and hydrogel lenses during eye closure

MR O'Neal, KA Polse and MD Sarver

Corneal changes were monitored in 14 subjects following 3 hr of eye closure while wearing selected oxygen permeable rigid and hydrogel lenses. The mean increase in corneal thickness ranged from 82.5 to 29.5 microns for rigid lenses with oxygen transmissibilities (Dk/L) between 0.2 X 10(-9) and 57.0 X 10(-9) (cm/sec) (ml O2/ml X mmHg), respectively, and ranged from 82.5 to 23.5 microns for hydrogel lenses with Dk/L between 2.5 X 10(-9) and 70.0 X 10(-9) (cm/sec) (ml O2/ml X mmHg), respectively. No differences in the amount of swelling between rigid and hydrogel lenses of the same oxygen transmissibility were observed (t-test, P greater than 0.20). Combining the swelling data for both types of lenses shows that a minimum lens oxygen transmissibility of approximately 75 X 10(-9) (cm/sec) (ml O2/ml X mmHg) is necessary during eye closure to prevent contact lens induced edema. The estimated oxygen tension under a lens with this Dk/L value is 40 mmHg. Recovery of the cornea to baseline thickness follows a nonlinear time course, with the rate of dehydration decreasing as the cornea thins. For initial swelling of 40-54 microns, 55-69 microns, and 70 microns and above, the time to reach baseline thickness was 1.5, 2.0, and 2.5 hr, respectively. Effects on vision, corneal curvature, distortion, and epithelial integrity were not clinically significant during this short period of eye closure.


This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
K Hamilton, D Pye, S Hua, F Yu, J Chung, and Q Hou
The effect of contact lens induced oedema on the accuracy of Goldmann tonometry in a mature population
Br. J. Ophthalmol., December 1, 2007; 91(12): 1636 - 1638.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the Association for Research in Vision and Ophthalmology