Investigative Ophthalmology & Visual Science, Vol 25, 977-980, Copyright © 1984 by Association for Research in Vision and Ophthalmology
ARTICLES AND REPORTS |
JS Zigler Jr, M Mochizuki, T Kuwabara and I Gery
This report describes a procedure by which high performance liquid chromatographic (HPLC) techniques are used to obtain homogeneous S- antigen. Conventionally prepared S-antigen was purified further by fractionation on the anion exchange Mono-Q column followed by gel filtration on a TSK-3000 column. This procedure produced an S-antigen preparation, which appeared homogeneous by gel electrophoresis using the very sensitive silver staining method. The purified material retained its immunochemical and uveitogenic activity. The availability of homogeneous S-antigen will facilitate studies aimed at elucidating, at the molecular level, the mechanism by which S-antigen induces uveitis.