IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Beekhuis, W. H.
Right arrow Articles by McCarey, B. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beekhuis, W. H.
Right arrow Articles by McCarey, B. E.

Investigative Ophthalmology & Visual Science, Vol 26, 1634-1636, Copyright © 1985 by Association for Research in Vision and Ophthalmology


ARTICLES AND REPORTS

Hydration stability of intracorneal hydrogel implants

WH Beekhuis and BE McCarey

A hydrogel intracorneal lens for refractive keratoplasty must have predictable and stable optics when implanted in the corneal stroma. A series of experiments was performed to evaluate the hydrogel hydration stability when in the corneal stromal environment. Hydrogel ICLs of 54%, 63%, 66% and 71% water content showed no loss of hydration (by weight) after one week in the rabbit corneal stroma. In vitro experiments with hydrogel discs of 56%, 65%, 69.5% and 75% water content were subjected to swelling pressures ranging from 55 to 150 mmHg in a suction chamber. Only the hydrogel of 75% water content showed a significant loss of hydration at the physiologic swelling pressure of 55 mmHg. This study shows that hydrogel materials with up to 69.5% water content can be expected to be dimensionally stable when used in keratorefractive surgery.


This article has been cited by other articles:


Home page
Journal of Bioactive and Compatible PolymersHome page
E.M. D'urso and G. Fortier
New Bioartificial Polymeric Material: Poly(ethylene glycol) Cross-Linked with Albumin. I. Synthesis and Swelling Properties
Journal of Bioactive and Compatible Polymers, January 1, 1994; 9(4): 367 - 387.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the Association for Research in Vision and Ophthalmology