IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chylack, L. T.
Right arrow Articles by Tung, W. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chylack, L. T., Jr
Right arrow Articles by Tung, W. H.

Investigative Ophthalmology & Visual Science, Vol 27, 118-122, Copyright © 1986 by Association for Research in Vision and Ophthalmology


ARTICLES AND REPORTS

Inexpensive stereoscopic CCRG camera for lens/cataract photography in vitro

LT Chylack Jr and WH Tung

In 1978 the American Cooperative Cataract Research Group (CCRG) adopted a stereoscopic camera system for photographing human cataracts in vitro based upon a Zeiss OPMI 1 operating microscope (Carl Zeiss, Inc.; Oberkochen, West Germany). Photographs obtained with this system were used to classify human cataractous change according to the standardized CCRG protocol. Classification data correlated with laboratory data furthered the attempt to define the biochemical or biophysical basis for specific types of cataractous change. Presently, the high cost of this camera (exceeding $20,000) precludes its use by many laboratories wishing to do human lens research. This study describes an inexpensive (less than $2,200) alternative camera for this type of photography. Adjacent frames on the film strip constitute stereo pairs which can be viewed in a modified stereo viewer. In the original CCRG camera both members of a stereo pair were included in the same frame. The quality of the stereo images obtained with this new system nearly equals that with the original Zeiss system. It is hoped that this inexpensive system will allow more scientists to participate in CCRG-related research and increase the supply of intracapsularly extracted cataracts available to all collaborating CCRG scientists.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the Association for Research in Vision and Ophthalmology