IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Karesh, J. W.
Right arrow Articles by Nirankari, V. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Karesh, J. W.
Right arrow Articles by Nirankari, V. S.

Investigative Ophthalmology & Visual Science, Vol 27, 1284-1288, Copyright © 1986 by Association for Research in Vision and Ophthalmology


ARTICLES AND REPORTS

An improved method for the delivery of artificial tears using an infusion pump

JW Karesh and VS Nirankari

Patients with markedly decreased or absent tear duct production require the frequent instillation of artificial tear preparations. Through animal experiments, a new method has been developed for the continuous infusion of these solutions. In this procedure, the canalicular system is intubated with fenestrated silastic tubing, which is subcutaneously tunnelled and then attached to a miniaturized and computerized pumping device. This makes it possible for a predetermined volume of solution to be automatically and continuously delivered. Using this technique, artificial tear solution was instilled at a rate of 1.75 microliter/min, a rate approximately the normal basic tear secretion rate (0.5-2.2 microliters/min). This resulted in a 14% increase in tear flow from preoperative values. This represents a 74% increase in tear secretion rates for patients with keratoconjunctivitis sicca. None of the experimental animals developed subcutaneous infections, dacryocystitis, or corneal ulcers. By utilizing the normal anatomy of the lacrimal drainage system, this new technique: does not compromise the conjunctival cul-de-sac or the salivary system, avoids the inconvenience of previous external devices, and allows for the automatic instillation of predetermined volumes of artificial tear solutions.