IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hitzenberger, C. K.
Right arrow Articles by Gnad, H. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hitzenberger, C. K.
Right arrow Articles by Gnad, H. D.

Investigative Ophthalmology & Visual Science, Vol 34, 1886-1893, Copyright © 1993 by Association for Research in Vision and Ophthalmology


ARTICLES AND REPORTS

Measurement of the axial length of cataract eyes by laser Doppler interferometry

CK Hitzenberger, W Drexler, C Dolezal, F Skorpik, M Juchem, AF Fercher and HD Gnad
Institut fur Medizinische Physik, Universitat Wien, Austria.

PURPOSE. To examine the applicability of the recently developed laser Doppler interferometry technique for measuring the axial length of cataract eyes in a realistic clinical situation. To determine the performance of the instrument as a function of cataract grade. To compare the results to those of ultrasound methods. METHODS. A total of 196 cataract eyes of 100 patients were examined. The axial eye length was determined by laser Doppler interferometry and by two different ultrasound techniques, the applanation technique and the immersion technique. The cataract grade was determined by a commercial instrument that measures backscattered light. RESULTS. Laser Doppler interferometry worked very well except in the cases of the highest cataract grades (4% of the eyes of this study were not measurable because of a too-high lens density). Only 3.5% of the other eyes were not measurable because of fixation problems of the patients. The precision of laser Doppler interferometry is not influenced by the cataract grade (except the highest grade). The standard deviation of the geometric eye length is approximately 20 microns. Linear regression analysis revealed a very good correlation of laser Doppler interferometry and ultrasonic measurements, but a systematic difference was found. The eye lengths measured by laser Doppler interferometry were about 0.18 mm longer than those measured by the immersion technique and about 0.47 mm longer than those measured by the applanation technique. CONCLUSION. These differences are attributed to the laser Doppler interferometry results including the retinal thickness and indentation of the cornea by the applanation technique. The main advantages of the laser Doppler interferometry technique are high precision, high accuracy, and more comfort for the patient because it is a noncontact method, anesthesia is unnecessary, and the risk of corneal infection is avoided.


This article has been cited by other articles:


Home page
IOVSHome page
J. R. Lewis, A. E. Knellinger, A. M. Mahmoud, and T. F. Mauger
Effect of Soft Contact Lenses on Optical Measurements of Axial Length and Keratometry for Biometry in Eyes with Corneal Irregularities
Invest. Ophthalmol. Vis. Sci., August 1, 2008; 49(8): 3371 - 3378.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. S. Schuman
Introducing Wolfgang Drexler, the 2007 Recipient of the Cogan Award
Invest. Ophthalmol. Vis. Sci., December 1, 2007; 48(12): 5339 - 5339.
[Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
H Eleftheriadis
IOLMaster biometry: refractive results of 100 consecutive cases
Br. J. Ophthalmol., August 1, 2003; 87(8): 960 - 963.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. L. Hougaard, L. Kessel, B. Sander, K. O. Kyvik, T. I. A. Sorensen, and M. Larsen
Evaluation of Heredity as a Determinant of Retinal Nerve Fiber Layer Thickness as Measured by Optical Coherence Tomography
Invest. Ophthalmol. Vis. Sci., July 1, 2003; 44(7): 3011 - 3016.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
J Santodomingo-Rubido, E A H Mallen, B Gilmartin, and J S Wolffsohn
A new non-contact optical device for ocular biometry
Br. J. Ophthalmol., April 1, 2002; 86(4): 458 - 462.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the Association for Research in Vision and Ophthalmology