IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McLaren, J. W.
Right arrow Articles by FitzSimon, J. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McLaren, J. W.
Right arrow Articles by FitzSimon, J. S.

Investigative Ophthalmology & Visual Science, Vol 37, 966-975, Copyright © 1996 by Association for Research in Vision and Ophthalmology


ARTICLES AND REPORTS

Continuous measurement of intraocular pressure in rabbits by telemetry

JW McLaren, RF Brubaker and JS FitzSimon
Department of Ophthalmology, Mayo Clinic, Rochester, Minnesota 55905, USA.

PURPOSE. Intraocular pressure (IOP) is dynamic and can be influenced by the use of tonometers. The authors developed a technique to implant a telemetric pressure transducer to measure IOP continuously in unrestrained rabbits. METHODS. A commercial telemetric pressure transducer was implanted subcutaneously on the dorsal neck, between the scapulae, of pigmented rabbits. A fluid-filled catheter that conducts pressure to the transducer was routed to the orbit subcutaneously and implanted in the anterior chamber through a limbal opening. The transducer measured pressure and broadcast this information by amplitude modulation radio to a receiver in the animal's cage. Data were recorded at a rate of 50 or 100 samples per second for 60 seconds to study transient changes in IOP to tonometry, or for 15 seconds every 2.5 minutes to study circadian behavior of IOP. RESULTS. Intraocular pressure was recorded from seven rabbits for 180 to 370 days. Within 3 to 8 days of implant surgery, IOP began to follow a circadian rhythm: IOP decreased after room lights were turned on at 00:00 CT and increased after they were turned off at 12:00 CT. (The term CT refers to circadian time and begins at 00:00 CT when lights are turned on.) The maximum difference in IOP between light and dark phases ranged from 6.4 mm Hg to 16.6 mm Hg. When the lighting cycle was advanced by 6 hours, the time of nocturnal rise in IOP also advanced, but it did so gradually over 10 to 14 days. CONCLUSIONS. The implanted pressure transducer provides a convenient, preinvasive method to measure and study IOP in unrestrained experimental animals. This technique will be used to study circadian variations in IOP, the effects of environmental stimuli, and the oculohypotensive effects of therapeutic agents.


This article has been cited by other articles:


Home page
IOVSHome page
M. Aihara, J. D. Lindsey, and R. N. Weinreb
Effect on Diurnal Intraocular Pressure Variation of Eliminating the {alpha}-2 Adrenergic Receptor Subtypes in the Mouse
Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 929 - 933.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
Z. He, B. V. Bui, and A. J. Vingrys
The Rate of Functional Recovery from Acute IOP Elevation
Invest. Ophthalmol. Vis. Sci., November 1, 2006; 47(11): 4872 - 4880.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
H. A. Reitsamer, C. Zawinka, and M. Branka
Dopaminergic Vasodilation in the Choroidal Circulation by D1/D5 Receptor Activation
Invest. Ophthalmol. Vis. Sci., March 1, 2004; 45(3): 900 - 905.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. H. K. Liu, R. P. Bouligny, D. F. Kripke, and R. N. Weinreb
Nocturnal Elevation of Intraocular Pressure Is Detectable in the Sitting Position
Invest. Ophthalmol. Vis. Sci., October 1, 2003; 44(10): 4439 - 4442.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
D. L. Nickla, C. F. Wildsoet, and D. Troilo
Diurnal Rhythms in Intraocular Pressure, Axial Length, and Choroidal Thickness in a Primate Model of Eye Growth, the Common Marmoset
Invest. Ophthalmol. Vis. Sci., August 1, 2002; 43(8): 2519 - 2528.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
H. A. Reitsamer and J. W. Kiel
Effects of Dopamine on Ciliary Blood Flow, Aqueous Production, and Intraocular Pressure in Rabbits
Invest. Ophthalmol. Vis. Sci., August 1, 2002; 43(8): 2697 - 2703.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
R. N Rizq, W.-H. Choi, D. Eilers, M. M Wright, and B. Ziaie
Intraocular pressure measurement at the choroid surface: a feasibility study with implications for implantable microsystems
Br. J. Ophthalmol., July 1, 2001; 85(7): 868 - 871.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
K. Okada and D. S. Gregory
Hydroxyamphetamine Increases Intraocular Pressure in Rabbits
Arch Ophthalmol, February 1, 2001; 119(2): 235 - 239.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the Association for Research in Vision and Ophthalmology