IOVS Am. J. Clin. Nutrition
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tuunanen, T. H.
Right arrow Articles by Tervo, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tuunanen, T. H.
Right arrow Articles by Tervo, T.

Investigative Ophthalmology & Visual Science, Vol 37, 1810-1814, Copyright © 1996 by Association for Research in Vision and Ophthalmology


ARTICLES AND REPORTS

Effect of photorefractive keratectomy on the accuracy of pneumatonometer readings in rabbits

TH Tuunanen, P Hamalainen, M Mali, O Oksala and T Tervo
University Eye Hospital, Helsinki, Finland.

PURPOSE. To determine whether measurement of intraocular pressure (IOP) using a pneumatonometer is reliable after myopic 5 or 15 D excimer laser photoablation in rabbits. METHODS. Ten rabbits underwent 5 D myopic photorefractive keratectomy (PRK) of the left eye. Another seven rabbits underwent 15 D PRK. The right eye served as a control. The diameter of each PRK was 5 mm. Rabbits were examined 2.5 to 3 months later under general anesthesia. Eyes were cannulated, and the IOP was maintained at 5 to 40 mm Hg and measured using an intracameral manometer and a pneumatonometer at each pressure level; approximately 50 pressure points were formed. Readings of the two techniques were compared. RESULTS. Linear regression analysis comparing manometric and pneumatonometric readings revealed the following data in eyes with 5 D corrections (n = 10): correlation coefficient (r) = 0.926, slope = 1.058, and intercept = -3.133. The values of the unoperated control eyes were: r = 0.900, slope = 0.962, and intercept = -1.010. The following results were obtained in eyes with 15 D photoablation (n = 7): r = 0.876, slope 1.133, and intercept -3.147. Values for the control eye were: r = 0.885, slope = 1.175, and intercept = -3.497. When the manometer and pneumatonometer readings of all animals were compared, the adjusted squared correlation coefficient was 79%. When the variabilities associated with the animals and the PRK procedure (pooled 5 and 15 D corrections) were taken into account, adjusted squared correlation coefficient increased from 8% to 87%. CONCLUSIONS. Photorefractive keratectomy as high as 15 D/5 mm had only a minor effect on pneumatonometer readings in rabbits, indicating that the elastic properties of the cornea related to the accuracy of pneumatonometry were not significantly altered. Postoperative IOP monitoring with tonometers, based on flattening of the cornea under pressure, is accurate after PRK.


This article has been cited by other articles:


Home page
IOVSHome page
K. S. Lim, S. S. Wickremasinghe, M. F. Cordeiro, C. Bunce, and P. T. Khaw
Accuracy of Intraocular Pressure Measurements in New Zealand White Rabbits
Invest. Ophthalmol. Vis. Sci., July 1, 2005; 46(7): 2419 - 2423.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
A C Browning, A Bhan, A P Rotchford, S Shah, and H S Dua
The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology
Br. J. Ophthalmol., November 1, 2004; 88(11): 1395 - 1399.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the Association for Research in Vision and Ophthalmology