IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Spierer, A.
Right arrow Articles by Martinowitz, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Spierer, A.
Right arrow Articles by Martinowitz, U.

Investigative Ophthalmology & Visual Science, Vol 38, 543-546, Copyright © 1997 by Association for Research in Vision and Ophthalmology


ARTICLES AND REPORTS

Reattachment of extraocular muscles using fibrin glue in a rabbit model

A Spierer, I Barequet, M Rosner, AS Solomon and U Martinowitz
Goldschleger Eye Institute, Sackler School of Medicine, Tel Aviv University, Sheba Medical Center, Tel-Hashomer, Israel.

PURPOSE: Reattaching extraocular muscles by the conventional suturing method may be complicated by scleral perforation. The attachment of extraocular muscles, using fibrin sealants, avoids such risk. The authors evaluated the use of fibrin sealant in a laboratory rabbit model. METHODS: Fifty-eight eyes of 29 rabbits were used in the study. In both eyes of each rabbit, the superior rectus muscle was disinserted, recessed, and either sutured or reattached to the globe by fibrin sealant. Two groups of eyes were compared. In one group (42 eyes), the recessed muscle was reattached using fibrin sealant. In the second group (16 eyes), sutures were used to reattach the recessed muscle to the globe. The insertion of the superior rectus muscle was examined 14 days after surgery, and histopathologic evaluation was performed 6 weeks after the surgery. RESULTS: Although in the sutured muscle group no slippage from the original placement was found, it was found in the group in which fibrin glue was used. The muscle slippage was greater at the small muscle recessions and smaller at the large muscle recessions. For muscle recession of 6 mm or more, the average muscle slippage was 0.12 +/- 0.28 mm, which was not statistically different from the suture group (P = 0.0828). CONCLUSIONS: Fibrin sealant was found to be effective for extraocular muscle reattachment only in large muscle recessions. However, in small muscle recessions the glue was not strong enough to overcome the contractive strength of the muscle.


This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
M E Mulet, J L Alio, M M Mahiques, M M Mahiques, and J M Martin
Adal-1 bioadhesive for sutureless recession muscle surgery: a clinical trial
Br. J. Ophthalmol., February 1, 2006; 90(2): 208 - 212.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
E. Tonelli Jr, H. C. de Almeida, and E. A. Bambirra
Tissue Adhesives for a Sutureless Fadenoperation: An Experimental Study in a Rabbit Model
Invest. Ophthalmol. Vis. Sci., December 1, 2004; 45(12): 4340 - 4345.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
J. N. Bloom, M. T. Duffy, J. B. Davis, and K. M. McNally-Heintzelman
A Light-Activated Surgical Adhesive Technique for Sutureless Ophthalmic Surgery
Arch Ophthalmol, November 1, 2003; 121(11): 1591 - 1595.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the Association for Research in Vision and Ophthalmology