Investigative Ophthalmology & Visual Science, Vol 38, 1304-1313, Copyright © 1997 by Association for Research in Vision and Ophthalmology
ARTICLES AND REPORTS |
W Drexler, A Baumgartner, O Findl, CK Hitzenberger, H Sattmann and AF Fercher
Institut fur Medizinische Physik, Universitat Wien, Austria.
PURPOSE: To demonstrate the feasibility of measuring the anterior structures of the human eye by partial coherence interferometry and to determine its precision for eyes under normal and cycloplegic conditions. METHODS: The dual-beam version of partial coherence interferometry, a recently developed noninvasive optical ranging technique, enables high resolution measurements of several intraocular distances with unprecedented precision. A modified, more sensitive scanning version of this technique was used to assess the central and peripheral corneal thickness, the anterior chamber depth, and the lens thickness of 20 healthy, emmetropic to moderately myopic eyes. Furthermore the anterior structures of three eyes were measured under cycloplegia (1% cyclopentolate) to investigate the influence on the precision of this technique after suppression of residual accommodations. RESULTS: The mean geometric precision (standard deviation) of the measurement of the central corneal thickness was 0.29 micron (range, 0.22 micron to 0.38 micron) and 0.43 micron (range, 0.27 micron to 0.56 micron) for the peripheral corneal thickness at a distance 2 mm from its apex. The precision for measuring the anterior chamber depth and the lens thickness for fixation at infinity was 8.7 microns (range, 3.9 microns to 16.8 microns) and 8.9 microns (rang, 2.9 microns to 14.4 microns) for noncycloplegic eyes and 1.9 microns (range, 1.7 microns to 2 microns) and 1.4 microns (range, 0.7 micron to 1.8 microns) for cycloplegic eyes, respectively. CONCLUSIONS: The dual- beam partial coherence interferometry enables fast, noninvasive, submicrometer precision biometry of the anterior segment of the eye. The precision of determining the anterior chamber depth and the lens thickness is more than one order of magnitude better than that of the currently used ultrasound and optical techniques, and it can be improved by a factor of 5 by using cycloplegia.
This article has been cited by other articles:
![]() |
M. G. Wirtitsch, O. Findl, H. Heinzl, and W. Drexler Effect of Dorzolamide Hydrochloride on Central Corneal Thickness in Humans With Cornea Guttata Arch Ophthalmol, October 1, 2007; 125(10): 1345 - 1350. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Bolz, A. Prinz, W. Drexler, and O. Findl Linear relationship of refractive and biometric lenticular changes during accommodation in emmetropic and myopic eyes Br. J. Ophthalmol., March 1, 2007; 91(3): 360 - 365. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Tong, S.-M. Saw, J.-K. Siak, G. Gazzard, and D. Tan Corneal Thickness Determination and Correlates in Singaporean Schoolchildren Invest. Ophthalmol. Vis. Sci., November 1, 2004; 45(11): 4004 - 4009. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. G. Wirtitsch, O. Findl, B. Kiss, V. Petternel, H. Heinzl, and W. Drexler Short-term Effect of Dorzolamide Hydrochloride on Central Corneal Thickness in Humans With Cornea Guttata Arch Ophthalmol, May 1, 2003; 121(5): 621 - 625. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Nichols and P. E. King-Smith Thickness of the Pre- and Post-Contact Lens Tear Film Measured In Vivo by Interferometry Invest. Ophthalmol. Vis. Sci., January 1, 2003; 44(1): 68 - 77. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. E. King-Smith, B. A. Fink, N. Fogt, K. K. Nichols, R. M. Hill, and G. S. Wilson The Thickness of the Human Precorneal Tear Film: Evidence from Reflection Spectra Invest. Ophthalmol. Vis. Sci., October 1, 2000; 41(11): 3348 - 3359. [Abstract] [Full Text] |
||||
![]() |
R. Bovelle, S. C. Kaufman, H. W. Thompson, and H. Hamano Corneal Thickness Measurements With the Topcon SP-2000P Specular Microscope and an Ultrasound Pachymeter Arch Ophthalmol, July 1, 1999; 117(7): 868 - 870. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |