IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Drexler, W.
Right arrow Articles by Fercher, A. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Drexler, W.
Right arrow Articles by Fercher, A. F.

Investigative Ophthalmology & Visual Science, Vol 38, 1304-1313, Copyright © 1997 by Association for Research in Vision and Ophthalmology


ARTICLES AND REPORTS

Submicrometer precision biometry of the anterior segment of the human eye

W Drexler, A Baumgartner, O Findl, CK Hitzenberger, H Sattmann and AF Fercher
Institut fur Medizinische Physik, Universitat Wien, Austria.

PURPOSE: To demonstrate the feasibility of measuring the anterior structures of the human eye by partial coherence interferometry and to determine its precision for eyes under normal and cycloplegic conditions. METHODS: The dual-beam version of partial coherence interferometry, a recently developed noninvasive optical ranging technique, enables high resolution measurements of several intraocular distances with unprecedented precision. A modified, more sensitive scanning version of this technique was used to assess the central and peripheral corneal thickness, the anterior chamber depth, and the lens thickness of 20 healthy, emmetropic to moderately myopic eyes. Furthermore the anterior structures of three eyes were measured under cycloplegia (1% cyclopentolate) to investigate the influence on the precision of this technique after suppression of residual accommodations. RESULTS: The mean geometric precision (standard deviation) of the measurement of the central corneal thickness was 0.29 micron (range, 0.22 micron to 0.38 micron) and 0.43 micron (range, 0.27 micron to 0.56 micron) for the peripheral corneal thickness at a distance 2 mm from its apex. The precision for measuring the anterior chamber depth and the lens thickness for fixation at infinity was 8.7 microns (range, 3.9 microns to 16.8 microns) and 8.9 microns (rang, 2.9 microns to 14.4 microns) for noncycloplegic eyes and 1.9 microns (range, 1.7 microns to 2 microns) and 1.4 microns (range, 0.7 micron to 1.8 microns) for cycloplegic eyes, respectively. CONCLUSIONS: The dual- beam partial coherence interferometry enables fast, noninvasive, submicrometer precision biometry of the anterior segment of the eye. The precision of determining the anterior chamber depth and the lens thickness is more than one order of magnitude better than that of the currently used ultrasound and optical techniques, and it can be improved by a factor of 5 by using cycloplegia.


This article has been cited by other articles:


Home page
Arch OphthalmolHome page
M. G. Wirtitsch, O. Findl, H. Heinzl, and W. Drexler
Effect of Dorzolamide Hydrochloride on Central Corneal Thickness in Humans With Cornea Guttata
Arch Ophthalmol, October 1, 2007; 125(10): 1345 - 1350.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
M. Bolz, A. Prinz, W. Drexler, and O. Findl
Linear relationship of refractive and biometric lenticular changes during accommodation in emmetropic and myopic eyes
Br. J. Ophthalmol., March 1, 2007; 91(3): 360 - 365.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
L. Tong, S.-M. Saw, J.-K. Siak, G. Gazzard, and D. Tan
Corneal Thickness Determination and Correlates in Singaporean Schoolchildren
Invest. Ophthalmol. Vis. Sci., November 1, 2004; 45(11): 4004 - 4009.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
M. G. Wirtitsch, O. Findl, B. Kiss, V. Petternel, H. Heinzl, and W. Drexler
Short-term Effect of Dorzolamide Hydrochloride on Central Corneal Thickness in Humans With Cornea Guttata
Arch Ophthalmol, May 1, 2003; 121(5): 621 - 625.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. J. Nichols and P. E. King-Smith
Thickness of the Pre- and Post-Contact Lens Tear Film Measured In Vivo by Interferometry
Invest. Ophthalmol. Vis. Sci., January 1, 2003; 44(1): 68 - 77.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
P. E. King-Smith, B. A. Fink, N. Fogt, K. K. Nichols, R. M. Hill, and G. S. Wilson
The Thickness of the Human Precorneal Tear Film: Evidence from Reflection Spectra
Invest. Ophthalmol. Vis. Sci., October 1, 2000; 41(11): 3348 - 3359.
[Abstract] [Full Text]


Home page
Arch OphthalmolHome page
R. Bovelle, S. C. Kaufman, H. W. Thompson, and H. Hamano
Corneal Thickness Measurements With the Topcon SP-2000P Specular Microscope and an Ultrasound Pachymeter
Arch Ophthalmol, July 1, 1999; 117(7): 868 - 870.
[Abstract] [Full Text] [PDF]