IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sydenham, M. M.
Right arrow Articles by Hirst, L. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sydenham, M. M.
Right arrow Articles by Hirst, L. W.

Investigative Ophthalmology & Visual Science, Vol 38, 1485-1492, Copyright © 1997 by Association for Research in Vision and Ophthalmology


ARTICLES AND REPORTS

Measurement of ultraviolet radiation at the surface of the eye

MM Sydenham, MJ Collins and LW Hirst
Center for Eye Research, School of Optometry, Queensland University of Technology, Australia.

PURPOSE: A new method for the measurement of ultraviolet radiation that reaches the surface of the eye is described. METHODS: The technique uses contact lenses produced from the ultraviolet-sensitive plastic polysulfone. Two types of polysulfone contact lenses (9 mm and 12 mm in diameter) were manufactured from a polysulfone rod. The 9-mm polysulfone contact lens could be calibrated and used to determine the ocular-to-ambient exposure ratio in a fashion similar to polysulfone film badges. The 12-mm polysulfone contact lens was designed as a "piggy-back" lens and required a larger diameter polymethlylmethacrylate carrier lens to fit the eye adequately. A method of in vivo stabilization was developed to minimize lens rotation. RESULTS: During four wearing trials, the ratio of ocular-to- ambient ultraviolet exposure ranged from 4% to 23%. CONCLUSIONS: Contact lenses manufactured from polysulfone offer the potential to study the exposure of the eye to ultraviolet radiation. The smaller diameter lens can measure an average ocular exposure, whereas the larger, stabilized, piggy-back design may allow regional dose assessment across the entire lens surface.


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
D. P. Fleming, J. E. Walsh, L. A. Moore, J. P. Bergmanson, and D. McMahon
A novel sensor array for field based ocular ultraviolet radiation measurements
Radiat Prot Dosimetry, June 1, 2006; 118(3): 265 - 274.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
L. S. Kwok, V. A. Kuznetsov, A. Ho, and M. T. Coroneo
Prevention of the Adverse Photic Effects of Peripheral Light-Focusing Using UV-Blocking Contact Lenses
Invest. Ophthalmol. Vis. Sci., April 1, 2003; 44(4): 1501 - 1507.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the Association for Research in Vision and Ophthalmology