IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bonanno, J. A.
Right arrow Articles by Soni, P. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bonanno, J. A.
Right arrow Articles by Soni, P. S.
(Investigative Ophthalmology and Visual Science. 2002;43:371-376.)
© 2002 by The Association for Research in Vision and Ophthalmology, Inc.

Estimation of Human Corneal Oxygen Consumption by Noninvasive Measurement of Tear Oxygen Tension While Wearing Hydrogel Lenses

Joseph A. Bonanno1, Thomas Stickel1, Tracy Nguyen1, Trina Biehl1, Donna Carter1, William J. Benjamin2 and P. Sarita Soni1

1 From the Borish Center for Ophthalmic Research, Indiana University, School of Optometry, Bloomington, Indiana; and the 2 Eye Physiology and Ocular Prosthetics Laboratory, School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama.

PURPOSE. To devise a procedure for direct estimation of corneal oxygen consumption in human subjects.

METHODS. Tear oxygen tension (PO2) was measured at the posterior surface of two standard hydrogel contact lenses (38% water, 0.2 and 0.06 mm thick, oxygen transmissibility [Dk/t] = 4.2 and 14 x 10-9 cm · mL O2/mL · sec · torr) and one newly available hydrogel-silicone polymer lens (Dk/t = 99 x 10-9). The oxygen-sensitive dye, Pd-meso-tetra (4-carboxyphenyl) porphine, bound to bovine serum albumin, was incubated with the lenses overnight. The lenses, coated with the protein–dye complex, were placed on four subjects’ eyes, and tear PO2was measured in the open eye and after 5 minutes of eye closure, using a time–domain phosphorescence measurement system. Given the tear PO2, lens Dk/t, and corneal thickness, oxygen consumption (QC, in mL O2/cm3 · sec) could be calculated from established oxygen diffusion models.

RESULTS. Protein-dye complex bound to the lens surface enabled reporting of tear PO2 for long periods. As expected, estimated tear PO2 was higher in subjects wearing lenses with higher Dk/t: mean open-eye PO2 = 30.6 ± 3.1 and 8.1 ± 1.3 torr for the thin and thick hydrogel lenses, respectively, and 97.6 ± 22.9 torr for the hydrogel-silicone lens. After 5 minutes of eye closure, tear PO2 was significantly reduced and reached a new steady state in approximately 20 seconds after eye opening. Fitting a single exponential model to the data and extrapolating to t = 0 provided an estimate of PO2 under the closed lid for the thin hydrogel (PO2 = 7 ± 2.3 torr) and the hydrogel-silicone lens (PO2 = 22.6 ± 4 torr). After 5 minutes of eye closure with the thick hydrogel lens, tear PO2 remained constant for ~10 seconds after eye opening (mean PO2 = 3.9 ± 0.7) before increasing to a new steady state. This delay could be accounted for by the time needed for oxygen to diffuse to the posterior surface of the lens. Calculated QC ranged from 2.2 x 10-4 to 3.7 x 10-6 mL O2/cm3 · sec) at the highest and lowest PO2s, respectively, and is comparable to previous in vitro and in vivo estimates.

CONCLUSIONS. Tear PO2 behind hydrogel lenses can be measured in human subjects using the phosphorescence of the porphyrin-protein complex bound to the lens surface. The method is simple, fast, reliable, and noninvasive, allowing quick and direct estimates of QC. In addition to contact lens wear, this method should be useful for examining the effects of disease, surgery, or topical drugs on the corneal oxygen consumption rate.