IOVS AJP: Lung Cellular and Molecular Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:2941-2948.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.03-0131

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boote, C.
Right arrow Articles by Meek, K. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boote, C.
Right arrow Articles by Meek, K. M.

Collagen Fibrils Appear More Closely Packed in the Prepupillary Cornea: Optical and Biomechanical Implications

Craig Boote, Sally Dennis, Richard H. Newton, Hina Puri, and Keith M. Meek

From the Department of Optometry and Vision Sciences, Cardiff University, Cardiff, Wales, United Kingdom.

PURPOSE. The size and organization of stromal collagen fibrils influence the biomechanical and optical properties of the cornea and hence its function. How fibrillar structure varies with position across the cornea has not been fully characterized. The present study was designed to quantify the collagen fibril spacing and diameter across the normal human cornea and to relate this to the properties of the tissue.

METHODS. Small-angle x-ray diffraction was used to map in detail the variation in fibril spacing and fibril diameter along orthogonal medial–lateral and inferior–superior meridians of five normal human corneoscleral discs.

RESULTS. Mean fibril diameters remained constant across all corneas up to the limbus, whereupon a sharp increase was observed. However, mean fibril spacing across the central 4 x 3 mm (prepupillary) cornea measured 5% to 7% lower than in the peripheral cornea.

CONCLUSIONS. Collagen fibrils in the prepupillary cornea appear to be more closely packed than in the peripheral cornea. Anisotropy in fibril packing across the cornea has potential implications for the transparency and refractive index of the tissue. Biomechanically, it is possible that the higher packing density of stress-bearing collagen fibrils in the prepupillary cornea is necessary for maintaining corneal strength, and hence curvature, in a region of reduced tissue thickness. By inference, these results could have important implications for the development of corneal models for refractive surgery.





This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
J M Gonzalez-Meijome, J Jorge, A Queiros, P Fernandes, R Montes-Mico, J B Almeida, and M A Parafita
Age differences in central and peripheral intraocular pressure using a rebound tonometer
Br. J. Ophthalmol., December 1, 2006; 90(12): 1495 - 1500.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
C. Tamburrelli, A. Giudiceandrea, A. S. Vaiano, C. G. Caputo, F. Gulla, and T. Salgarello
Underestimate of Tonometric Readings after Photorefractive Keratectomy Increases at Higher Intraocular Pressure Levels
Invest. Ophthalmol. Vis. Sci., September 1, 2005; 46(9): 3208 - 3213.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Association for Research in Vision and Ophthalmology