IOVS Journal of Nutrition
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2006;47:4842-4846.)
© 2006 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.06-0238

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Breyer, A.
Right arrow Articles by Mojon, D. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Breyer, A.
Right arrow Articles by Mojon, D. S.

A New 3D Monitor–Based Random-Dot Stereotest for Children

Armin Breyer,1 Xiaoyi Jiang,2 Adrian Rütsche,1 and Daniel S. Mojon1,3

1From the Laboratory of Experimental Oculography and the 3Department of Strabismology and Neuro-Ophthalmology, Kantonsspital, St. Gallen, Switzerland; and the 2Department of Computer Science, University of Münster, Münster, Germany.

PURPOSE. Objective testing for random-dot stereovision in preverbal children requires some type of dissociating glasses. Drawbacks of such methods are the alteration of natural visual conditions and sometimes nonacceptance of the glasses. For this reason, a new, natural method for random-dot stereopsis measurement was developed and tested.

METHODS. Random-dot circles (diameter 10 cm, crossed disparity of 0.34°) were generated on an autostereoscopic display and presented to 18 normal children (mean age, 5.1 ± 1.1 years), 8 with anisometropic amblyopia (mean age, 4.9 ± 1.3 years), 14 with infantile essential esotropia (mean age, 5.3 ± 0.7 years), and 16 with primary microstrabismus (mean age, 5.2 ± 1.4 years). While the position of the stimulus randomly changed among four possible locations, eye positions were recorded by infrared photo-oculography. If two or more consecutive saccades ends corresponded to the stimulus coordinates, a positive response was assumed. The results with the new test were compared with the ability to recognize the Lang I random-dot stereotest.

RESULTS. Twenty-four of 26 Lang I–positive children had positive responses (sensitivity of 92.3%), 29 of 30 Lang I–negative children had negative three-dimensional (3D) stimulus responses (specificity, 96.7%). The positive predictive value of the new test was 0.96 (95% CI, 0.79–0.99); the negative predictive value, 0.94 (95% CI, 0.78–0.99); and the overall accuracy, 0.95 (95% CI, 0.85–0.99).

CONCLUSIONS. This new 3D monitor–based test allows objective assessment of random-dot stereopsis in children older than 3 years.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the Association for Research in Vision and Ophthalmology