IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2006;47:574-581.)
© 2006 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.05-0872

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Xie, R. Z.
Right arrow Articles by Sweeney, D. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Xie, R. Z.
Right arrow Articles by Sweeney, D. F.

Two-Year Preclinical Testing of Perfluoropolyether Polymer as a Corneal Inlay

Ruo Zhong Xie,1 Margaret D. M. Evans,1,2 Barbara Bojarski,1 Timothy C. Hughes,1,3 Grace Y. Chan,1,3 Xuan Nguyen,1,3 John S. Wilkie,1,3 Keith M. McLean,1,3 Antti Vannas,1,4 and Deborah F. Sweeney1

1From the Vision Cooperative Research Centre, University of NSW, Sydney, Australia; 2CSIRO Molecular and Health Technologies, Sydney, Australia; 3CSIRO Molecular and Health Technologies, Clayton, Australia; and 4Central Military Hospital, Helsinki, Finland.

PURPOSE. To assess the long-term biocompatibility and optical clarity of a perfluoropolyether (PFPE) polymer as a corneal inlay.

METHODS. A 4-mm–diameter PFPE inlay was implanted under a microkeratome flap in the corneas of rabbits (n = 16) and maintained for predetermined time points of 6, 12, or 24 months. These were compared with normal (n = 3) and time-matched sham-wounded rabbit corneas (n = 8). All corneas were monitored clinically with a slit lamp. Histology was performed on all eyes on termination to assess the tissue response.

RESULTS. Some sham and implanted animals were discontinued from study 1 to 2 days after surgery because of flap dislodgement. Ten animals with PFPE inlays remained in the study, and 7 of these were maintained to their predetermined time point for up to 2 years (3 were discontinued because of peripheral corneal defects). The corneas of these 7 animals remained clear and healthy, tear film remained normal, and there were no signs of inflammation, neovascularization, or increased conjunctival redness. All inlays remained centered and optically clear (clarity 85% or greater). Histology showed PFPE was biostable. The epithelia of operated corneas were stratified but slightly thinned compared with those of normal corneas. Stromal tissue anterior and posterior to each inlay appeared normal. Keratocytes in the vicinity of the inlay were normal in distribution but showed increased vacuolation, indicating tissue repair after the surgery.

CONCLUSIONS. The PFPE polymer maintained a high level of optical clarity and showed long-term biocompatibility for up to 2 years when implanted as an inlay in the rabbit cornea.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the Association for Research in Vision and Ophthalmology