IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2006;47:1778-1784.)
© 2006 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.05-0869

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wilson, L. B.
Right arrow Articles by Stone, R. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wilson, L. B.
Right arrow Articles by Stone, R. A.

The Relation of Axial Length and Intraocular Pressure Fluctuations in Human Eyes

Lorri B. Wilson,1,2 Graham E. Quinn,1,2 Gui-shuang Ying,2 Ellie L. Francis,1 Gregor Schmid,3 An Lam,1 Josh Orlow,1 and Richard A. Stone1

1From the Division of Pediatric Ophthalmology, The Children’s Hospital of Philadelphia, and 2Department of Ophthalmology, Scheie Eye Institute, University of Pennsylvania, Philadelphia, Pennsylvania; and the 3Pennsylvania College of Optometry, Philadelphia, Pennsylvania.

PURPOSE. To determine in human eyes whether diurnal fluctuations in axial length are related to fluctuations in intraocular pressure (IOP) by studying these fluctuations in both eyes of individual subjects and by assessing the regularity of both rhythms on two separate study days.

METHODS. Ten subjects, ages 18 to 24 years, underwent serial axial length and IOP measurements using highly precise, noncontact partial coherence interferometry and Goldmann applanation tonometry, respectively. Both eyes were measured at six 3-hour intervals during each of two study days, and significant fluctuations were modeled by sine curves.

RESULTS. Of the 40 data sets, 29 had significant axial length high–low differences and 32 had significant IOP high–low differences (ANOVA, P < 0.05 for each). The magnitude of the significant high–low differences were 38 ± 22 µm for axial length and 6.0 ± 1.9 mm Hg for IOP (mean ± SD). Neither axial length nor IOP fluctuations necessarily occurred bilaterally on the same day, and neither rhythm was regularly observed on two separate days in individual eyes. In eyes in which both parameters fluctuated on the same day, there were no correlations in the amplitude, period or phase of the two rhythms.

CONCLUSIONS. Both axial length and IOP fluctuate during the day much of the time in most subjects. However, diurnal IOP fluctuations do not appear to cause diurnal axial length fluctuations.





This article has been cited by other articles:


Home page
IOVSHome page
S. A. Read, M. J. Collins, and D. R. Iskander
Diurnal Variation of Axial Length, Intraocular Pressure, and Anterior Eye Biometrics
Invest. Ophthalmol. Vis. Sci., July 1, 2008; 49(7): 2911 - 2918.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the Association for Research in Vision and Ophthalmology