IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2007;48:1535-1542.)
© 2007 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.06-1192

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yu, C. Q.
Right arrow Articles by Rosenblatt, M. I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yu, C. Q.
Right arrow Articles by Rosenblatt, M. I.

Transgenic Corneal Neurofluorescence in Mice: A New Model for In Vivo Investigation of Nerve Structure and Regeneration

Charles Q. Yu and Mark I. Rosenblatt

From the Department of Ophthalmology and Vision Science, University of California Davis School of Medicine, Sacramento, California.

PURPOSE. To quantify the level of neuron-specific fluorescence in the corneas of transgenic mice expressing yellow fluorescent protein (YFP) driven by the thy1 promoter and examine the viability of using thy1-YFP mice as a model for studying nerve regeneration in vivo.

METHODS. The structure of corneal innervation in thy1-YFP mice visible with reporter gene fluorescence was compared with that visible with traditional immunofluorescence techniques. The percentage of corneal nerves with YFP fluorescence in wholemounted corneas and trigeminal neuron cultures was determined. Regeneration of fluorescent corneal neuronal processes after wounding was monitored in vivo.

RESULTS. In the mouse cornea, neuron-specific immunostaining determined that nerves enter the stroma in several bundles that then extend throughout the entire cornea. These stromal nerve bundles form a subbasal plexus beneath the corneal epithelium. Fine nerves from this plexus travel superficially to the ocular surface. Neuron-specific expression of YFP allowed visualization of nearly all large nerve bundles of the stroma but only some of the many finer nerves of the subbasal plexus and surface. In the subbasal nerve plexus, 46% of total neuronal processes exhibited YFP neurofluorescence. In vitro, 22% of cultured trigeminal neurons exhibited YFP neurofluorescence. After corneal nerve transection, nerve processes distal to the site of injury degenerated, whereas those proximal to the site regenerated in a pattern different from original nerve architecture.

CONCLUSIONS. Thy1-YFP mice display neurofluorescence and provide a novel model for monitoring the patterning, injury, and growth of corneal nerves in vivo.





This article has been cited by other articles:


Home page
IOVSHome page
C. Q. Yu, M. Zhang, K. I. Matis, C. Kim, and M. I. Rosenblatt
Vascular Endothelial Growth Factor Mediates Corneal Nerve Repair
Invest. Ophthalmol. Vis. Sci., September 1, 2008; 49(9): 3870 - 3878.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
D. V. Patel and C. N. J. McGhee
In Vivo Laser Scanning Confocal Microscopy Confirms that the Human Corneal Sub-basal Nerve Plexus Is a Highly Dynamic Structure
Invest. Ophthalmol. Vis. Sci., August 1, 2008; 49(8): 3409 - 3412.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
L. Dvorscak and C. F. Marfurt
Age-Related Changes in Rat Corneal Epithelial Nerve Density
Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 910 - 916.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the Association for Research in Vision and Ophthalmology