IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2008;49:934-940.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.06-1418

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Kiekens, S.
Right arrow Articles by Verbraecken, J.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kiekens, S.
Right arrow Articles by Verbraecken, J.

Continuous Positive Airway Pressure Therapy Is Associated with an Increase in Intraocular Pressure in Obstructive Sleep Apnea

Stefan Kiekens,1 Veva De Groot,1 Tanja Coeckelbergh,1 Marie-José Tassignon,1 Paul van de Heyning,2,3 Wilfried De Backer,3,4 and Johan Verbraecken3,4

1From the Departments of Ophthalmology, 2Ear, Nose and Throat, and 4Pulmonary Medicine, and the 3Sleep Disorders Center, Antwerp University Hospital and University of Antwerp, Antwerp, Belgium.

PURPOSE. Several reports have demonstrated an association between glaucoma and obstructive sleep apnea (OSA), though the origin of this association remains unknown. In the present study, the influence of OSA and continuous positive airway pressure (CPAP) therapy on intraocular pressure (IOP) and ocular perfusion pressure (OPP) was examined.

METHODS. IOP, blood pressure, and pulse rate were measured every 2 hours during 24-hour sessions in 21 patients with newly diagnosed OSA. A first series of measurements was performed before CPAP therapy, and a second series was performed 1 month after the initiation of CPAP therapy. OPP was then calculated.

RESULTS. Baseline measurements showed a significant nycththemeral fluctuation in the average IOP, with the highest IOPs at night. After 1 month of CPAP therapy, the average IOP was significantly higher than baseline. The increase in overnight IOP was also significantly higher. A 24-hour IOP fluctuation of ≥8 mm Hg was found in 7 patients at baseline and in 12 patients during CPAP therapy. The mean difference between trough and peak IOP was 6.7 ± 1.5 mm Hg at baseline and 9.0 ± 2.0 mm Hg during CPAP therapy. Thirty minutes after CPAP cessation a significant decrease in IOP was recorded. There was a statistically significant decrease in mean OPP during CPAP therapy.

CONCLUSIONS. Patients with OSA demonstrated significant 24-hour IOP fluctuations, with the highest values at night. CPAP therapy causes an additional IOP increase, especially at night. Regular screening of visual fields and the optic disc is warranted for all patients with OSA, especially those treated with CPAP.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Association for Research in Vision and Ophthalmology