From the Department of Ophthalmology, Hebrew University, Hadassah Medical Center, Jerusalem, Israel.
| Abstract |
|---|
|
|
|---|
METHODS. Two pig eyes and two normal human eyes were processed using the "umbrella" technique, in which peripapillary concentric ring sections were obtained, at increasing diameters, all centered on the optic disc. Each histologic ring section contains a continuous circumferential 360° retinal slice, oriented approximately perpendicular to the retinal surface. Every histologic slice contains each axon of the retina, sectioned perpendicular to each axons long axis and at an equal set distance from the disc margin.
RESULTS. Ring sections from pig and human eyes are presented and correlated to known RNFL anatomy. For the two human eyes, peripapillary RNFL thickness was quantified and plotted, resulting in the expected double-hump pattern.
CONCLUSIONS. The umbrella technique provides, on a single histologic section, all necessary information for quantifying the entire RNFL layer of that eye, in a standardized fashion. This technique can simplify the process of analyzing the RNFL thickness histologically, assist in obtaining a normative database of RNFL thickness in humans, and be implemented as a histologic end point in animal studies evaluating new treatment modalities for glaucoma.
Although much has been published on imaging of the RNFL, little is known about true measurements of RNFL thickness. Of the six studies published to date on histologic quantification of RNFL thickness in primate eyes3 4 5 6 and human eyes,7 8 no two studies have approached the issue of sectioning (and processing) the retina in the same way.
Morgan et al.6 and Dichtl et al.8 sectioned the posterior pole horizontally, while Ogden5 sectioned it vertically. Varma et al.7 divided the optic disc and peripapillary retina into four quadrants, centered on the optic disc, and subsequently shaved sections off the edges of these quadrants, while Quigley and Addicks4 trephined (punched out) small circular retinal patches at predetermined locations around the disc, in a hexagonal configuration. In these studies, relatively few eyes were processed, and a limited number of RNFL thickness values were obtained for each of these eyes. The lack of a standardized sectioning and processing approach, and the different species studied (human and primate eyes) all limit comparisons across studies and highlight the technical difficulties involved.
In an attempt to standardize the way in which the RNFL might be analyzed histologically, let us consider the following problem: Assuming that a comprehensive, high resolution, RNFL thickness map is obtainable histologically for a particular eye, which portions of this map would deserve the most attention in relevance to glaucoma diagnosis and staging?
Knowledge gained from RNFL imaging (including confocal scanning laser ophthalmoscopy, scanning laser polarimetry, and optical coherence tomography [OCT]1 9 ) suggests that much can be learned by analyzing the RNFL thickness values along a predetermined ring set at a specific distance from the optic disc margin. Figure 1A shows a scanning laser polarimetry (GDx-VCC; Laser Diagnostics Technologies, San Diego, CA) RNFL thickness map of a 20° x 20° (roughly 7 x 7 mm) area centered on the optic disc. Although this map contains a large amount of relevant RNFL thickness data, the analysis and parameters routinely calculated stem primarily from RNFL thicknesses located along a peripapillary measurement ring with an outer edge diameter of 3.2 mm (Fig. 1B) . Likewise, the OCT (Carl Zeiss Meditec, Dublin, CA) measurement ring is set at 3.4 mm.
|
| Methods |
|---|
|
|
|---|
Two human eyesa right eye from a 60-year-old white male and a left eye from a 58-year-old white malewere obtained for research purposes from an eye bank. These eyes were fixed in 4% buffered formaldehyde 10.5 and 4.5 hours after death, respectively. Consent for the use of tissues in medical research was obtained from the immediate family. Tissue harvesting was performed according to the regulations for obtaining and handling human tissue for research purposes and in accordance with the tenets of the Declaration of Helsinki for research involving human subjects. Approval for this study was obtained from the institutional Human Subject Committee. A detailed postmortem history was obtained, in which known eye diseases, previous eye surgery, chronic eye medications, diabetes or any other systemic diseases that may affect retinal morphology were all denied. Macroscopic examination of the eyes excluded gross disease.
Sectioning the Globes
The globes were initially opened anterior to the equator, but posterior to the ora serrata, such that the optic disc was approximately at the center of the posterior cup. Portions of the vitreous were mechanically removed when necessary, and the neurosensory retina was then gently separated from the underlying retinal pigment epithelium with a blunt spatula, from the periphery toward the disc. Occasional chorioretinal adhesions were gently dehisced, avoiding tears in the neurosensory retina, rarely with portions of the RPE remaining adherent to the neurosensory retina. Figure 2 illustrates the "umbrella" technique developed for this study, transforming a relatively flat (spherical) configuration of the peripapillary retina into a closed-funnel orientation. This three-dimensional transformation is the core maneuver underlying the new technique. Optic disc orientation was maintained by leaving a rim of sclera around it.
|
Image Analysis
The ring sections used for RNFL thickness quantification were digitally photographed through a standard light microscope. Multiple high-magnification photographs were taken successively along each ring section, later manually aligned to form a composite image of each histologic slide with higher resolution than would have been possible had the entire slide been photographed at once. A 1-mm bar accompanied each composite photograph, providing a true measurement scale at the histologic section plane. Each digital composite image was later processed with an analysis software program developed in-house for digitally extracting RNFL thickness data at numerous equidistant locations around the inner circumference of each ring section. Measurements were taken on screen using digital calipers (CorelDraw, ver.11; Corel Corp., Ottawa, Ontario, Canada) after caliper calibration against the 1-mm bar. A second operator rechecked all measurements.
Retinal orientation for the human sections was extrapolated from the combined knowledge of the eye (RE versus LE), the orientation in which the block was sectioned (from the disc outwards), identification of the two temporal vascular arcades, and identification of the macula, showing a multilayered ganglion-cell layer region. For the human sections, the precise circumference along the inner retinal border was digitally measured, and then, at equidistant locations along this circumference line, RNFL thickness measurements were obtained with a digital on-screen caliper. Measurements were taken perpendicular to the retinal surface. The RNFL edges were defined such that the innermost edge of the RNFL was determined as the inner limiting membrane, whereas the outer edge was localized as the line joining the innermost extent of the nuclei of the innermost layer of ganglion cells. In the event that the RNFL layer was split, a correction for the empty space was made, such that the final measurement corresponded to actual RNFL tissue, digitally subtracting any empty spaces resulting from cleavage within the RNFL layer. However, most often these occasional splits (cleavage planes) occurred between the RNFL layer and the ganglion cell layer, so that the RNFL layer remained intact. In areas in which a major blood vessel interrupted the RNFL tissue, a RNFL measurement was not taken, but was replaced instead with the numerical average of the RNFL thickness measurements from the two adjacent data points.
| Results |
|---|
|
|
|---|
|
|
|
|
| Discussion |
|---|
|
|
|---|
The umbrella technique described in this report provides ring sections of the peripapillary retina, each providing all the necessary information for quantifying the RNFL layer of that eye, on a single histologic slide. Stated otherwise, this single peripapillary ring section contains all axons of that eye, each sectioned perpendicular to its long axis, at a specified set distance from the optic disc margin, providing the means to quantify focal RNFL dropout in a standardized and familiar layout. To be precise, all axons of the eye are included in the ring section, except the axons of those few ganglion cells with cell bodies that lie within the boundaries of the ring itself.
The umbrella technique presented in this report is not limited in the choice of section thickness, staining chosen, or type of microscopy used. Also, in addition to RNFL analysis, it can serve to determine and quantify various characteristics of other layers of the neurosensory retina.
Several limitations should be mentioned regarding the ability of this novel tissue processing technique to quantify RNFL thickness, limitations that are mostly common to all histologic analyses of the RNFL. These include postmortem and tissue-processing artifacts, such as swelling, shrinkage, expansion, distortion, and autolysis. In addition, several limitations are specific to the umbrella techniqueamong them, the need to ascertain that the funnellike retina configuration is indeed tight and that perpendicularity is maintained during processing. The importance of verifying perpendicularity of the sectioning plane, as well as potential tissue distortion, collapse, and breakage from mobilizing fixated tissue, are all crucial. Ring-sections at the disc margin and very adjacent to it, are difficult to obtain using this technique. Retinal folds during processing that are oriented parallel to the disc margin may result in inaccurate topographic representation. Although the tissue-processing technique minimizes the occurrence of such folds, this can be further studied by comparing the distance of blood vessel bifurcations from the disc margin in the fundus photograph, to their location in successive histologic sections. Last, and perhaps most important, the unique approach presented herein necessitates that the entire eye be dedicated to this sectioning approach, making it difficult to combine this method with other more conventional posterior segment histologic sectioning approaches or to use tissue sectioned previously.8
Future goals related to this newly introduced technique include standardizing the processing, sectioning, and analysis stages; validating the reproducibility of this new technique; determining normative values for RNFL thickness in normal human eyes; using it as a histologic endpoint for glaucoma research in animal models; and exploring ways of counting RNFL axons and measuring axonal diameter distribution at the retinal level.
| Footnotes |
|---|
Disclosure: E.Z. Blumenthal, None
The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C.
1734 solely to indicate this fact.
Corresponding author: Eytan Z. Blumenthal, Department of Ophthalmology, Hadassah University Hospital, PO Box 12000, Jerusalem 91120, Israel; eblumenthal{at}md.huji.ac.il.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
M. J. Cohen, E. Kaliner, S. Frenkel, M. Kogan, H. Miron, and E. Z. Blumenthal Morphometric Analysis of Human Peripapillary Retinal Nerve Fiber Layer Thickness Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 941 - 944. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||