|
|
||||||||
1From the Instituto de Neurociencias de Alicante, Universidad Miguel Hernández-CSIC, Campus de San Juan, San Juan de Alicante, Spain.; and the 2Departmentos de Óptica and de 3Bioquímica, Escuela Universitaria de Óptica, Universidad Complutense de Madrid, Madrid, Spain.
| Abstract |
|---|
|
|
|---|
METHODS. Six healthy subjects participated in the study. Tear secretion was measured in both eyes by the Schirmers test conducted under control conditions and after stimulation of the center of the cornea and the temporal conjunctiva with a gas esthesiometer. Mechanical stimulation consisted in three pulses of 3 seconds duration of warmed air (at 34°C on the eye surface) applied at moderate (170 mL/min) and high (260 mL/min) flow rates. Cold thermal stimulation was made with cooled air that produced a corneal temperature drop of 1°C or 4.5°C. Chemical (acidic) stimulation was performed with a jet of gas containing a mixture of 80% CO2 in air.
RESULTS. The basal volume of tear secretion increased significantly (P < 0.05, paired t-test) after stimulation of the cornea with high-flow mechanical stimuli (260 mL/min), intense cooling pulses (4.5°C), and chemical stimulation (80% CO2). The same stimuli were ineffective when applied to the conjunctiva. Moderate mechanical (170 mL/min) and cold (1°C) stimulation of the cornea or the conjunctiva did not change significantly the volume of tear secretion.
CONCLUSIONS. Reflex tear secretion caused by corneal stimulation seems to be chiefly due to activation of corneal polymodal nociceptors, whereas selective excitation of corneal mechanonociceptors or cold receptors appears to be less effective in evoking an augmented lacrimal secretion. Conjunctival receptors stimulated at equivalent levels do not evoke an increased tear secretion.
The sensory innervation of the cornea and the conjunctiva includes different functional classes of sensory receptor fibers identified as mechanonociceptor, polymodal nociceptor, and cold receptor fibers.6 7 8 9 In addition, a small number of low-threshold mechanoreceptor nerve endings are found in the limbus and perilimbal bulbar conjunctiva.7 Separate stimulation of the various types of ocular sensory afferents evokes sensations of different quality that may contain a component of irritation, depending on the intensity and modality of the stimulus.10 11 However, the relative contribution to reflex tear secretion of the different functional subpopulations of corneal and conjunctival sensory afferents is still undefined. The purpose of this study was to compare the changes in tear secretion induced by selective stimulation of the functionally distinct types of sensory receptor fibers supplying the cornea and bulbar conjunctiva.
| Materials and Methods |
|---|
|
|
|---|
Esthesiometry and Tear Collection
The cornea and the conjunctiva were stimulated with a gas esthesiometer.12 For this purpose, three gas pulses lasting 3 seconds each, of variable flow rate, temperature, and CO2 content, were applied sequentially (interval <0.5 seconds) to the center of the cornea or to the temporal side of the bulbar conjunctiva. Subjects were asked to avoid blinking during the application of the three gas pulses. Mechanical stimulation was obtained with air puffs of moderate (170 mL/min) or high (260 mL/min) flow. Chemical stimulation was performed using gas pulses that contained 80% CO2 in air, applied at subthreshold flow rates. In both cases, the gas was warmed inside the probe to reach the surface of the cornea at a temperature of 34°C.10 12 Air pulses, cooled to evoke temperature decreases on the surface of the cornea or conjunctiva of 1°C or 4.5°C, and at a gas flow below mechanical threshold, were used for thermal stimulation.10 11 Subjects were requested to define the sensation evoked by the stimulus as irritating or innocuous. They also described in their own words the characteristics of the experienced sensation.
Eleven measurements of tear secretion per eye were performed in each subject, distributed in 11 separate sessions: 1 without stimulation and 10 in which the various forms of stimulation (mechanical moderate, mechanical strong, cold moderate, cold strong, and chemical) were applied to the cornea or the conjunctiva (Table 1) . Basal tear production was measured once at the beginning of the experimental series (session 1). The order of the remaining sessions was established at random. In every session, one eye was randomly selected and stimulated sequentially while tears of that eye were collected; 15 minutes later, the same procedure was repeated in the second eye. At least 4 hours were allowed between successive sessions.
|
| Results |
|---|
|
|
|---|
|
Moderate or strong stimuli of all modalities applied to the conjunctiva always evoked a conscious sensation, although strong stimuli were less effective than in the cornea in producing a well-defined sensation of irritation.11
| Discussion |
|---|
|
|
|---|
Mechanical stimulation of the cornea with the gas esthesiometer using air pulses of 170 mL/min represents a moderate mechanical stimulation, close to threshold. Such low-intensity stimuli activate, weakly and almost exclusively, a fraction of polymodal nociceptor fibers in the cat and evoke in humans an ill-defined sensation of contact that includes a low irritation component.10 14 In contrast, mechanical stimuli of higher intensity, as those performed with air puffs of 260 mL/min, excites in cats most if not all polymodal nociceptor fibers and also the population of high-threshold mechanonociceptors.10 In humans, the same gas pulses elicited a distinct sensation of irritation. The present study demonstrates that only these high-flow stimuli triggered a reflex increase in tear secretion, which suggests that recruitment of a significant part of the population of polymodal nociceptor fiber and/or of mechanonociceptor fibers is needed to trigger the reflex response leading to an increased production of tears.
Gas pulses containing a high concentration of CO2 (80%) form carbonic acid in the ocular surface, thus producing a local increase in proton concentration.6 10 14 This pH decrease acts as a chemical stimulus that activates vigorously the polymodal nociceptor fibers but not the mechanonociceptors or cold receptors.6 7 10 11 15 With 80% CO2 pulses, reflex tear secretion was augmented to the same levels than when a strong mechanical stimulation was applied. This observation further supports the hypothesis that stimulation of polymodal nociceptor fibers is the main mechanism for triggering the tearing reflex, whereas mechanonociceptors seem to play, at best, a secondary role in this response. This observation is not surprising, considering that pure mechanonociceptor fibers of the cornea are not abundant (approximately 30% of the A-delta population in the feline cornea9 ) and give in response to a sustained stimulus, a transient discharge composed by one or few nerve impulses, in contrast with A-
and C polymodal nociceptors that fire a continuous, irregular train of nerve impulses as long as the stimulating pulse is maintained. Moreover, they represent more than 60% of the total population of corneal nerve afferents.
Stimulation of the cornea with moderate cooling (local temperature reductions of <2°C) did not increase the basal volume of tears. Small reductions of corneal temperature surface within that limit are known to activate exclusively the population of corneal cold receptor fibers and to evoke sensations of non-noxious cooling. When stronger cold is applied, a fraction of polymodal nociceptors is also recruited.10 16 Correspondingly, the sensation acquired an irritating quality10 and, as shown in this work, tear secretion was significantly increased.
In the conjunctiva, none of the stimuli that were effective in the cornea evoked an augmented tear secretion. Electrophysiological studies of the scleral innervation are still incomplete, but have evidenced the presence in this tissue of essentially the same functional types of sensory fibers that are found in the cornea, although the overall density of nerve endings in the conjunctiva appears to be comparatively lower (Aracil A, et al. IOVS 2001;42:ARVO Abstract 3561).9 17 Sensation thresholds for mechanical stimulation in the conjunctiva are higher than in the cornea,11 18 19 presumably due to the lower innervation density and to the fact that nerve endings innervating the conjunctival epithelium are more distant from the surface and therefore less exposed to stimuli than in the cornea.15 In addition, the rich vascularization of the conjunctiva possibly contributes to buffer thermal and pH effects, thereby decreasing the effectiveness of cold and CO2 stimuli in activating sensory afferents. However, strong mechanical, cold, and acidic stimuli of the conjunctiva evoked a distinct sensation of irritation in our subjects, showing that polymodal nociceptors are also excited by these stimuli.11 Thus, the differences detected in our experiments between reflex tear secretion evoked by corneal and conjunctival stimulation may be due to a reduced recruitment of polymodal nociceptor fibers in the case of the conjunctiva, below the level required to activate the reflex tearing pathway. Alternatively, afferents innervating the bulbar conjunctiva may not be connected with the central neurons of the relay stations involved in the reflex control of tear secretion and would be thus unable to modify tearing. In our experimental conditions, the relative contribution to the observed changes in lacrimal secretion, of the various tissues involved in tear formation (lacrimal glands, goblet cells, epithelia)20 was not evaluated. Thus, the degree of modification of fluid production by reflex stimulation of the autonomic fibers in each of these tissues could not be determined.
The contribution of the background impulse activity of corneal and conjunctival sensory nerve afferents to the basal lacrimal secretion, through a neural loop connected with the autonomic efferent fibers directed to the lacrimal glands is unknown. Topical anesthesia of the cornea and conjunctiva reduces basal production of tears by 25% to 40%,21 22 thus speaking in favor of a tonic neural stimulation on the lacrimal secretion originated at the sensory receptors of the ocular surface. It is noteworthy though that only cold thermoreceptor corneal fibers discharge spontaneously at rest, whereas mechano- and polymodal nociceptors fire occasional impulses or remain silent unless noxious stimulation is applied to the cornea, thus suggesting that cold receptor fibers provide the main afferent input for the hypothetical neural component of the basal tear secretion. Nevertheless, moderate cooling of the cornea, which evokes a marked increase in the discharge of corneal cold receptor fibers7 did not induce an augmented tear secretion. It can be speculated that the fraction of the basal lacrimal secretion that depends on a neural input from cold receptor fibers is already activated at its maximum level by the ongoing activity of these fibers at rest. In contrast, reflex secretion caused by irritating stimuli may follow a separate afferent pathway, whose peripheral branch is composed chiefly of corneal polymodal nociceptor fibers.
| Footnotes |
|---|
Submitted for publication December 17, 2003; revised February 17 and March 8, 2004; accepted March 9, 2004.
Disclosure: M.C. Acosta, None; A. Peral, None; C. Luna, None; J. Pintor, None; C. Belmonte, None; J. Gallar, None
The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C.
1734 solely to indicate this fact.
Corresponding author: M. Carmen Acosta, Instituto de Neurociencias de Alicante, Universidad Miguel Hernández-CSIC, Campus de San Juan, Aptdo. 18, 03550 San Juan de Alicante, Spain; mcarmen.acosta{at}umh.es.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
J. Lilja, H. Lindegren, and A. Forsby Surfactant-Induced TRPV1 Activity A Novel Mechanism for Eye Irritation? Toxicol. Sci., September 1, 2007; 99(1): 174 - 180. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Peral, G. Carracedo, M. C. Acosta, J. Gallar, and J. Pintor Increased levels of diadenosine polyphosphates in dry eye. Invest. Ophthalmol. Vis. Sci., September 1, 2006; 47(9): 4053 - 4058. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |