|
|
||||||||
1From the Department of Pharmaceutical Sciences, College of Pharmacy, and the 3Department of Ophthalmology, University of Nebraska Medical Center, Omaha, Nebraska; and 2Novartis Pharmaceuticals, East Hanover, New Jersey.
| Abstract |
|---|
|
|
|---|
METHODS. VEGF mRNA and protein expression in ARPE-19 cells was evaluated in the presence of 0 to 10 µM celecoxib, and cytotoxicity of celecoxib on ARPE-19 and RF6A cells was evaluated over a 0- to 100-µM concentration range. Celecoxib-PLGA microparticles were prepared by a modified solvent evaporation technique, sterilized by 25 kGy of
-irradiation, and characterized for size,
potential, drug loading, and in vitro release. Normal and streptozotocin-diabetic male Sprague-Dawley rats were divided into five groups: normal, diabetic, diabetic+placebo, normal+celecoxib, and diabetic+celecoxib. Phosphate-buffered saline (PBS) containing celecoxib-PLGA microparticles, placebo PLGA microparticles, or plain PBS in one eye was injected into the posterior subconjunctival (periocular) space in rats under anesthesia. Sixty days after administration, the animals were killed, and retinal PGE2 secretion, VEGF protein, and bloodretinal barrier leakage were estimated. Blood cell counts, blood chemistry and histology were used to assess the safety of the microparticulate system.
RESULTS. Celecoxib (up to 25 µM) did not cause significant cytotoxicity in ARPE-19 or RF6A cells. Nanomolar concentrations of celecoxib reduced VEGF mRNA and VEGF protein secretion. Celecoxib-PLGA microparticles (diameter: 1140 ± 15 nm), containing 14.93% ± 0.21% of celecoxib sustained in vitro drug release and in vivo drug levels in the retina for 60 days. Diabetes elevated PGE2 secretion, VEGF protein, the vitreous-plasma protein ratio, and bloodretinal barrier leakage by 3-, 1.7-, 3.1-, and 2.7-fold, and celecoxib-PLGA microparticles significantly reduced these elevations by 40%, 50%, 40%, and 50%, respectively. Neither the placebo-treated eyes nor the contralateral eyes in celecoxib-PLGA microparticle-treated rats showed significant effects. Celecoxib-PLGA or placebo-PLGA particles had no effect on the body weight or blood sugar level of rats. The celecoxib-PLGA microparticles did not cause any changes in blood cell counts or chemistry and caused no histopathological damage to the retina or periocular tissues.
CONCLUSIONS. Nanomolar concentrations of celecoxib can inhibit VEGF mRNA and protein expression from ARPE-19 cells. Periocular celecoxib microparticles are useful sustained drug delivery systems for inhibiting diabetes-induced elevations in PGE2, VEGF, and bloodretinal barrier leakage. The periocular celecoxib-PLGA microparticles are safe and do not cause any damage to the retina.
Previous studies demonstrated an elevation in the PGE2 levels in the diabetic retina.6 7 Increased PGE2 levels are associated with increased breakdown of the bloodretinal barrier.8 9 We have shown that the elevation in PGE2 secretion from diabetic rat retinas is a Cox-2- and not a Cox-1-mediated phenomenon.7 Thus, administration of Cox-2 selective inhibitors may be an effective strategy in reducing prostaglandin-induced retinal inflammation and bloodretinal barrier breakdown during diabetes.
VEGF is thought to be a major factor responsible for increased vascular leakage in the initial stages and neovascularization in the later proliferative stages of diabetic retinopathy. It has been demonstrated that the VEGF mRNA upregulation occurs within 1 to 2 weeks after induction of diabetes in rats,10 11 and the elevation is observed even at 6 months after diabetes in rat models.12 In addition, vitreal VEGF is elevated in proliferative retinopathy models and in humans with proliferative diabetic retinopathy.13 14 It is also elevated in the aqueous of human subjects with diabetic retinopathy in both the proliferative and nonproliferative forms, and the levels in the vitreous are higher than in the aqueous.15 Thus, VEGF is an attractive pharmacological target in the treatment of diabetic retinopathy. The increased VEGF levels could be at least in part due to increased secretion of inflammatory mediators such as prostaglandins. Diabetes induces the production of inflammatory mediators via the cyclooxygenase pathway in the rat retina.10 The products of cyclooxygenase metabolism can stimulate VEGF secretion in tumor cells, cultured retinal cells, and cultured tissues.16 17 18 19 20 21 22 Many cell types in the eye including the retinal pigment epithelial cells, retinal capillary pericytes, retinal microvascular endothelial cells, Müller cells, and ganglion cells produce VEGF.23 The RPE cells show elevation in VEGF mRNA early in the course of diabetic retinopathy.23 In addition, Cox-2 expression is observed in the RPE cells in human diabetic subjects as well as primary cultures.24 Thus, inhibition of the Cox-2 enzyme system is likely to reduce prostaglandin generation, VEGF expression and vascular leakage. In this study, we sought to assess whether celecoxib, a selective Cox-2 inhibitor can inhibit VEGF expression in cultured human RPE cells (ARPE-19).
Oral administration of celecoxib reduces VEGF mRNA and vascular leakage in rats.10 However, long-term oral administration of high doses of Cox-2 inhibitors such as celecoxib may lead to systemic toxicity.25 26 27 Alternative routes, such as the intravitreal and periocular routes, can provide significantly higher local levels of celecoxib to the retina.28 The periocular routes are safer than the intravitreal route, which may lead to complications such as retinal detachment, endophthalmitis, and cataracts.28 We have previously shown that the retinal availability of celecoxib is 54-fold higher with the periocular route of administration than with the systemic route.29 Diabetic retinopathy is a chronic disorder, and prolonged therapy with multiple doses is required for its treatment. Multiple administrations via the periocular routes are uncomfortable for the patient and can increase the chances of complications. Therefore, a sustained drug delivery system, which could maintain the drug levels for a prolonged period, would be beneficial.
We have demonstrated that biodegradable particulate systems sustain retinal drug delivery of a corticosteroid as well as celecoxib during a 2-week study.30 31 In another study, we observed that microparticles and nanoparticles
200 nm, are almost completely retained in the periocular space for at least 60 days.32 Therefore, another objective of this study was to ascertain whether periocularly administered biodegradable celecoxib microparticles reduce diabetes-induced PGE2 secretion, VEGF expression, and breakdown of the bloodretinal barrier in a rat model of early background diabetic retinopathy at the end of 60 days of diabetes.
| Materials and Methods |
|---|
|
|
|---|
Cell Culture
ARPE-19 and RF6A cells were cultured in DMEM-F12 medium containing 10% fetal bovine serum, 100 U/mL penicillin, 100 mg/mL streptomycin, and 2 mM L-glutamine. The medium was changed every 2 days, and all studies were conducted with day-8 cells of passages 20 to 30 for ARPE-19 and passages 35 to 45 for RF6A.
VEGF Secretion Studies
VEGF secretion studies in ARPE-19 cells were performed as previously described.33 Briefly on day 8, after 12 hours of quiescence, the cell monolayers were incubated with celecoxib (010 µM) for 12 hours. The culture medium was collected at 12 hours and secreted VEGF was quantified by an ELISA method using a kit purchased from Research Diagnostics Inc. The kit is capable of detecting the secreted human VEGF isoforms VEGF165 and VEGF121. The secreted VEGF levels were normalized to the total protein content in the cell lysates. The kit has no cross-reactivity with recombinant human VEGF-B196.
RT-PCR and Real-Time RT-PCR
To determine whether celecoxib reduces VEGF mRNA levels in ARPE-19 cells, semiquantitative RT-PCR was used as previously described.33 Briefly, after an initial quiescence period of 12 hours in serum-free medium, confluent ARPE-19 cells, in T-25 flasks, were treated with celecoxib (010 µM). After the 12-hour treatment, total RNA was isolated with a commercial kit (RNA Stat-60; Tel-Test, Friendswood, TX). Total RNA (3 µg) was used to amplify VEGF mRNA. The primers used can detect all the splice variants of VEGF. The products were separated by electrophoresis on a 2% agarose gel, and VEGF165 (584 bp) and VEGF121 (452 bp) mRNAs were identified and quantified with densitometric analysis (Nucleovision Imaging System; Nucleotech, San Mateo, CA). The VEGF mRNA expression was normalized to the expression of 18S rRNA, an internal control.
For real-time relative quantitative RT-PCR, isoform-specific primers for VEGF165 were used.34 RNA (1 µg), isolated as just described, was used in the RT reaction and converted to cDNA using with the reverse transcriptase kit (TaqMan; ABI). cDNA equivalent to 200 µg RNA was then used in the real-time PCR reaction (SYBR Green Universal PCR Master Mix and Prism 7700 Sequence Detection System; ABI). The VEGF165 signal was normalized to that of 18s rRNA. The 2
Ct method was used to calculate the change (x-fold) in gene expression with no treatment (0 µM celecoxib) taken as the control.35 In addition to VEGF mRNA expression, mRNA expressions of VEGF-receptors 1 and 2 were assessed in ARPE-19 cells using real-time PCR with the primer sequences described previously.36
MTT Assay
The cytotoxicity of celecoxib in ARPE-19 and RF6A cells was assessed by incubating the day-8 cell monolayers with 0 to 100 µM celecoxib for 12 hours after quiescence. The cell viability was assessed with a previously described colorimetric MTT assay.33
Preparation of Celecoxib-PLGA and Placebo PLGA Microparticles
Celecoxib-PLGA microparticles were prepared using a previously described modified emulsion solvent evaporation method.31
Drug Loading
The loading efficiency of celecoxib in the polymeric particles was determined by extracting and quantifying the encapsulated celecoxib. Briefly, celecoxib-polymeric particles (2 mg) were placed in a glass vial, and 4 mL methylene chloride was added and mixed thoroughly at room temperature for 24 hours. The resultant extract was evaporated to dryness under nitrogen, and the dried residue was reconstituted with 1000 µL acetonitrile-water mixture (70:30). This reconstituted solution was vortexed for 1 minute and centrifuged at 12,000g for 5 minutes, and 100 µL of the supernatant was injected into the HPLC column. Celecoxib was quantified with an HPLC method described previously.7 31
Sterilization of Particles
The celecoxib-PLGA microparticles and the placebo PLGA microparticles were sterilized by
-irradiation. The particles were kept in polypropylene tubes and irradiated in air at a rate of 230 Gy/min using a Picker V 90 60Co source (Picker International, Inc., Cleveland, OH) for a total dose of 25 kGy.37 Dry ice was used to prevent any increase in temperature during the procedure.
In Vitro Drug Release from Celecoxib-PLGA Particles
The in vitro release of celecoxib from the PLGA particles was performed at 37°C with dialysis membrane bags (molecular weight cutoff: 10,000; Spectrum Laboratory, Gardenia, CA), as described previously.30 Briefly, a 0.5-mL suspension of either plain celecoxib (20 µg) or celecoxib-PLGA particles containing 20 µg celecoxib was taken into the dialysis bag, and the unit was allowed to float in 50 mL of release medium (PBS [pH 7.4] containing 0.025% sodium azide as a preservative). At discrete time intervals, 1 mL of the release medium was removed and replaced with fresh release medium. The released celecoxib was analyzed by HPLC assay. The release between sterilized and nonsterilized celecoxib-PLGA particles was also compared.
Particle Size and
-Potential Measurement
The particle size and the
potential were measured with a
-potential analyzer (Zeta Plus; Brookhaven Instruments Ltd., New York, NY) that employs the dynamic light-scattering technique for particle size measurement. The software calculates the effective diameter based on the Stokes-Einstein equation as a diameter of an equivalent hydrodynamic sphere from z-average diffusion coefficients. The particle size measurements were performed after dilution in PBS.
Subconjunctival Administration
All animal studies were performed in male Sprague-Dawley rats weighing 150 to 180 g. The animals were divided into five groups: (1) normal rats that did not have diabetes and did not receive any microparticles; (2) diabetic rats that had diabetes but received no microparticles; (3) diabetic+placebo-treated rats that had diabetes and were injected with placebo PLGA microparticles; (4) normal+celecoxib-treated rats that did not have diabetes and received celecoxib-PLGA microparticles; and (5) diabetic+celecoxib-treated rats that were diabetic and received celecoxib-PLGA microparticles. Diabetes was induced by intraperitoneal injection of streptozotocin (60 mg/kg). The blood sugar level was assessed 24 hours after administration of streptozotocin, and the animals with blood sugar level above 250 mg/dL were deemed diabetic. One day after streptozotocin injection, the animals were anesthetized with an intraperitoneal injection of pentobarbital sodium (40 mg/kg). After this, 50 µL of sterile suspension of celecoxib-PLGA microparticles (equivalent to 750 µg celecoxib), placebo-PLGA microparticles (amount equivalent to celecoxib-PLGA microparticles), or plain PBS (pH 7.4) was injected into the posterior subconjunctival space of one eye (ipsilateral) using a 27-gauge needle. The normal+celecoxib microparticle group animals received microparticles equivalent to 750 µg of celecoxib on the same day as the diabetic animals received the microparticles. The animals were killed on day 60 after subconjunctival administration. Just before death, the blood sugar levels were tested again to confirm diabetic status. All the animal experiments were performed in compliance with the ARVO Statement for the Use of Animals in Ophthalmic and Vision Research.
PGE2 Secretion from Isolated Rat Retinas
On the 60th day after subconjunctival injection, the rats were euthanatized with pentobarbital sodium (250 mg/kg). The eyes were enucleated, and the retina was isolated immediately. The retinas were weighed and placed in 2-mL centrifuge tubes. PBS (200 µL) was added, and the retinas were incubated at 37°C in a metabolic incubator for 2 hours. After 2 hours, the tubes were centrifuged at 7000g, and the supernatant was used for PGE2 estimation with an ELISA kit according to the manufacturers recommendations (Cayman Chemicals). The secreted PGE2 levels were normalized to the wet retina weight.
Retinal VEGF Protein
The retinas were isolated and homogenized in 200 µL of PBS. The tubes were centrifuged at 7000g for 10 minutes (Marathon MicroA centrifuge; Fisher Scientific), and the supernatant was used for the estimation of VEGF (VEGF ELISA; R&D Systems; Minneapolis, MN). This kit detects the 164 and 120 isoforms of VEGF in the rats. The VEGF levels were normalized to the protein content measured using a protein estimation kit (Pierce; Rockford, IL). The kit has no cross-reactivity with recombinant mouse VEGF-B196 and 73.4% and 90.8% cross-reactivity with recombinant mouse VEGF164 and VEGF120, respectively.
BloodRetinal Barrier Leakage
Vitreous-Plasma Protein Ratio.
For the vitreous-to-plasma protein ratio, just before death, 1 mL of blood was withdrawn and placed into centrifuge tubes containing EDTA. The blood was centrifuged at 13,000g to separate the plasma. The supernatant was collected, diluted appropriately, and used for the plasma protein estimation. For the vitreal protein estimation, the eyes were enucleated after death, and the vitreous was isolated. The contents of the vitreous were centrifuged at 13,000g for 10 minutes, and the supernatant was diluted appropriately and used for protein estimation. The protein estimations were performed with the protein assay kit.
FITC-Dextran Leakage.
The bloodretinal barrier leakage was determined with an FITC-dextran leakage assay, as previously described, with some modifications.38 Briefly, after induction of deep anesthesia, the animals were injected intravenously with FITC-dextran (4.4 kDa, 50 mg/mL in PBS, 50 mg/kg body weight). After 10 minutes, the chest cavity was opened, and the animals were perfused with PBS (500 mL/kg body weight). Blood samples were collected immediately before perfusion. Immediately after perfusion, the retinas were dissected and homogenized, and the FITC-dextran was extracted with 750 µL of water. The extract was centrifuged at 7000 rpm for 10 minutes, and the supernatant (500 µL) was used to measure the fluorescence. Corrections for the blank were made by subtracting the fluorescence obtained from eyes of rats not injected with FITC-dextran. The amount of FITC-dextran in the samples was quantified with a standard curve of FITC-dextran in water. The amount of FITC-dextran in the retina was normalized to the retinal weight and to the plasma concentration of FITC-dextran. The bloodretinal barrier breakdown was calculated by using the following formula, as previously described.38
![]() |
Drug Level Estimation in Ocular Tissues
The celecoxib levels in plasma and in various ocular tissues, including the sclera-choroid, retina, vitreous, and cornea, were measured at 2 months after administration of celecoxib-PLGA microparticles in diabetic rats, by using liquidliquid extraction followed by an HPLC method described elsewhere.31
Safety of Periocular Microparticles
The safety of periocular microparticles was assessed by visual inspection, histology, and blood chemistry and blood count analysis between the normal rats injected with vehicle (PBS) and normal rats that were injected with celecoxib-PLGA microparticles. The visual inspection of the periocular tissue was performed to determine any overt inflammation of the tissue, including edema in the periocular area.
For the histologic analysis, the rats were deeply anesthetized with ketamine (75 mg/kg) and xylazine (10 mg/kg) by intraperitoneal injection, the heart was exposed, and the rats were perfused with 500 mL/Kg of 4% paraformaldehyde solution. The eyes were enucleated, and the conjunctiva and periocular tissues were removed and immersed in 10% formalin for 24 hours. After rehydration, the tissues were embedded in paraffin blocks and 7-µm-thick sections were cut. The sections were stained with H&E or Masson trichrome stain and viewed with a microscope (Axioscope 40; Carl Zeiss Meditec, Inc., Dublin, CA). The images were taken with a digital camera (HV-D25 using EPIX-XCAP lite V2.2 for Windows; Hitachi, Tokyo, Japan).
For the blood metabolic parameter assessment, the animals were anesthetized with ketamine-xylazine, and blood was collected from the left ventricle into heparinized tubes and submitted to the clinical laboratory at the University of Nebraska Medical Center for the analysis of blood chemistry and blood cell counts.
Morphometric Analysis of the Retina
Morphometric analysis was performed on the H&E-stained retinal sections prepared as above. Every third section containing the optic nerve was used in the analysis, for a total of four sections per animal. The sections were photographed at a total magnification of 50x. The morphometric analysis was performed on the retina from 0.5 to 1.5 mm superior and inferior to the optic nerve. Ten measurements for the superior retina and 10 measurements for the inferior retina with a total of 20 measurements per section were made. The readings from all four sections for each animal were averaged to get an average retinal thickness for that animal. The thickness of the neural retina (from photoreceptor layer to ganglion cell layer), outer nuclear layer (ONL), and inner nuclear layer (INL) were compared between normal rats and normal rats that were given celecoxib-PLGA microparticles. Morphometric software (Image Pro Plus; Silver Springs, MD) was used.
Data Analysis
Unless otherwise stated, all data are expressed as mean ± SD. The in vitro and in vivo comparisons between the five groups were made by one-way ANOVA followed by the Tukey post hoc analysis. The comparisons between the ipsilateral and contralateral eyes were made by a dependent-samples t-test. The results were considered statistically significant at P < 0.05. The data were analyzed on computer (SPSS 11.5 for windows; SPSS Inc., Chicago, IL).
| Results |
|---|
|
|
|---|
|
|
|
Potential, and Drug Encapsulation Efficiency of Celecoxib PLGA Particles
potential was 38 ± 0.56 mV. The celecoxib loading into the microparticles was 14.93% ± 0.12%, with a loading efficiency of 51.48% ± 0.42%.
In Vitro Drug Release from Celecoxib-PLGA Microparticles
The celecoxib microparticles released the drug in a biphasic manner over a period of 60 days. There was an initial burst release lasting for 3 days followed by a sustained release of celecoxib over the next 60 days. Approximately 50% of the entrapped drug was released in vitro at the end of 60 days (Fig. 4) . With the plain drug suspension, 100% celecoxib was released in vitro in 7 days with an average release rate of 2.65 µg/d or 13.25%/d (Fig. 4 , inset). In contrast, celecoxib-PLGA microparticles sustained drug levels during the 9-week in vitro release study with an average postburst release rate of 0.07 µg/d or 0.35%/d. The release rate was thus
38-fold lower for the microparticles than with the suspension dosage form. Thus, the polymer matrix plays a role in slowing the drug release rate, much beyond what is feasible based on the low aqueous solubility (37 µg/mL) of celecoxib.
|
-Irradiation on Drug Release from Celecoxib-PLGA Microparticles
Effect of Diabetes and Microparticles on Body Weight and Blood Sugar Levels of Rats
With the induction of diabetes, there was a significantly lower weight gain in the diabetic rats than in the normal rats. The weight gain was 71% at the end of 60 days in the normal rats and was reduced to a 7% weight gain at the end of 60 days in the diabetic rats. The treatment with celecoxib microparticles or placebo microparticles did not affect the weight gain. The blood sugar levels were significantly higher in the diabetic, diabetic+celecoxib, and diabetic+placebo groups than in the normal or normal+celecoxib groups (Table 1) .
|
|
Effect of Celecoxib-PLGA Microparticles on BloodRetinal Barrier Leakage
With 60 days of diabetes, there was a greater than threefold elevation in the vitreous-plasma protein ratio from 0.35 ± 0.07 to 1.17 ± 0.21 (Fig. 5C) . There was a
40% inhibition in the elevated ratio with the celecoxib microparticles (0.67 ± 0.08). The placebo microparticles did not have any effect. There was no difference in the vitreous/plasma protein ratio between normal and normal+celecoxib groups. The bloodretinal barrier leakage assessed using 4.4-kDa FITC-dextran indicated an increase in leakage from 12.9 ± 2.1 to 34.8 ± 4.4 µL/g per minute of plasma (Fig. 5D) . In the diabetic+placebo group the barrier breakdown was similar to the diabetic group with the leakage being 28.7 ± 6.9 µL/g per minute. There was a
50% inhibition of the vascular leakage in the ipsilateral eyes of the celecoxib-PLGA microparticle-treated group, but there was no significant decrease in the contralateral eyes.
Drug Levels in the Ocular Tissues
At the end of 60 days, celecoxib could be quantified in the diabetic, treated eye tissues including sclera-choroid, retina, vitreous, and the cornea. The drug levels in the ipsilateral eye were 0.66 ± 0.33, 0.79 ± 0.34, 0.23 ± 0.1, and 3.68 ±3.01 ng/mg tissue, respectively, in the sclera-choroid, retina, vitreous, and the cornea. The total tissue drug levels in the retina correspond to approximately 2 µM celecoxib. The celecoxib levels were below quantification limits in the plasma and the contralateral eye tissues.
Safety of Periocular Microparticles
The visual inspection of the periocular tissue (site of injection) did not reveal the presence of any inflammation, including redness and edema for the rats that were injected with celecoxib-PLGA microparticles.
The retina and the choroid appear normal in the histologic sections without any cellular infiltration, inflammation or atrophy of the retina (Fig. 6) . The Masson trichrome staining of the periocular tissue including the conjunctiva revealed no difference in collagen staining pattern between the control rats and rats that were injected with periocular celecoxib-PLGA microparticles (Fig. 6) .
|
|
|
| Discussion |
|---|
|
|
|---|
The bloodretinal barrier breakdown is a major cause of macular edema during the progression of diabetic retinopathy.44 Macular edema is associated with a loss of visual acuity.44 The retinas of human as well as diabetic rats show similarities in the early pathophysiological changes of diabetic retinopathy.45 46 47 Bloodretinal barrier leakage is thus common in the human disease and the streptozotocin rat model. Current therapies targeted toward macular edema, a consequence of the breakdown of the bloodretinal barrier, have not been satisfactory. Hence, there is a need to look for alternative therapies. The evaluation of bloodretinal barrier breakdown can be achieved through several experimental techniques. These techniques include the isotope-dilution method, the Evans blue assay, and measurement of extravasation of FITC-albumin.48 In addition, the measurement of the ratio of vitreal endogenous protein concentration to plasma protein concentration can be used to measure the extent of bloodretinal barrier breakdown.49 The information obtained about bloodretinal barrier breakdown can differ, based on the technique used.48 We have used two methods in the assessment of bloodretinal barrier breakdown: the vitreous/plasma protein ratio and the leakage of 4.4-kDa FITC-dextran. FITC-dextrans have been used in the assessment of the molecular size of the retinal vascular leakage in patients with posterior uveitis50 and in animal models of experimental choroidal neovascularization.51 In their study, Atkinson et al.50 report that the 4.4-kDa dextran did not penetrate the healthy bloodretinal barrier but leaked out form areas of macular edema, new retinal vessels, and swollen optic discs. This method has been used in previous studies with normal and streptozotocin diabetic rats38 52 53 and has been shown to have good sensitivity and quantitative predictability comparable to the Evans blue assay.38 Our results indicate that there is a breakdown of the bloodretinal barrier, evidenced by both the methods used. The extent of bloodretinal barrier breakdown is threefold and 2.7-fold, respectively, based on the vitreous-plasma protein ratio and the dextran leakage assay. The slightly higher bloodocular barrier breakdown indicated by the vitreous-plasma protein ratio could be because this method measures the protein concentration in the vitreous and not the retina, possibly accounting leakage from and bloodaqueous barriers. A limitation of using the vitreous to plasma protein ratio to indicate vascular permeability is highlighted by the observation that significant increases in vitreous protein have been observed in 1-month streptozotocin diabetic rats without any discernible eye disease.54 The FITC-dextran leakage measurement does not have this drawback. This study demonstrated the efficacy of the sustained-release celecoxib-PLGA microparticulate system in inhibiting vascular leakage, using both the methods mentioned herein, with the percentage of inhibition being 40% and 50%, respectively, for vitreous-plasma protein ratio and FITC-dextran leakage for assessment of barrier breakdown.
Although earlier studies have demonstrated that celecoxib is distributed in the eye after oral administration10 55 and have also demonstrated the efficacy of celecoxib in inhibiting diabetes-induced bloodretinal barrier leakage,10 the doses required to achieve therapeutic concentrations in the retina were very high. This is especially important because the use of selective Cox-2 inhibitors has been a recent matter of controversy due to their cardiovascular side effects.27 We have demonstrated previously that the dose-normalized AUC of celecoxib in the retina is 54-fold higher after periocular administration than after systemic administration.29 Thus, periocular delivery of celecoxib can provide higher retinal levels with a concurrent reduction in the plasma levels. The dose of celecoxib used in this study is low (750 µg/rat) and also involves only a one-time administration of the celecoxib-PLGA microparticulate delivery system. At this dose, with approximately 50% of drug expected to be released in 60 days, the measured concentration of celecoxib in the retina of the treated eye 60 days after administration is approximately 2 µM, which, even if largely bound to tissue, is likely to achieve therapeutic concentrations based on its ability to inhibit VEGF secretion and Cox-2 at nanomolar concentrations.
VEGF, an endothelium-specific mitogen, is known to play an important role in the pathogenesis of several retinal disorders, including diabetic retinopathy. Preclinical and clinical studies have demonstrated that VEGF is an important factor in the pathologic course of both background and proliferative diabetic retinopathy.15 56 57 58 Because VEGF is elevated in diabetic retinopathy, one purpose of this study was to assess the efficacy of celecoxib in inhibiting VEGF secretion from the retina. We investigated the effect of celecoxib on VEGF secretion in ARPE-19 cells, a human RPE cell line, in which we have demonstrated VEGF expression.59 The RPE cells form the outer barrier and constitutively express VEGF.60 Celecoxib at nanomolar concentrations inhibited the VEGF protein secretion (Fig. 3) as well as the VEGF mRNA expression (Fig. 2) in ARPE-19 cells. The inhibition of VEGF was at concentrations similar to the median inhibitory concentration IC50 of celecoxib in inhibiting Cox-2 (4090 nM).61 62 The inhibition of VEGF mRNA and protein secretion was not due to a cytotoxic effect, because celecoxib had no effect on cell viability up to a concentration of 25 µM (Fig. 1) . Cox-2 enzyme products like PGE2 are known to stabilize HIF1
,63 and translocate it to the nucleus. HIF1
acts as a potent transcription factor for several genes, including VEGF.64 Thus, at least in part, the inhibition of VEGF mRNA and protein secretion could be accounted for by the inhibition of Cox-2.
In our in vitro cytotoxicity studies, we observed no cytotoxicity up to 25-µM concentrations of celecoxib in both ARPE-19 and RF-6A cells. There was a dramatic increase in cytotoxicity at 50 µM and no difference between 50- and 100-µM concentrations. This cytotoxic effect is probably compound-solubility limited. The reported solubility of celecoxib in water at 37°C and pH 7.0 ranges from 3 to 7 µg/mL.65 66 Because the pKa of celecoxib is 11.2, a similar solubility is expected in physiological buffers at this temperature. This corresponds to a celecoxib concentration of 8 to 18 µM. In our studies, the solutions of celecoxib were made in ethanol at a concentration of 10 mM and then diluted to the required concentrations, which led to a maximum of 1% ethanol in the solution prepared. Cosolvents can increase the solubility of poorly soluble organic compounds. Indeed, celecoxib solubility has been shown to be increased by the cosolvents ethanol, glycerol and dimethyl sulfoxide (DMSO) up to 25 to 50 µM celecoxib.67 Around this concentration range, celecoxib may precipitate out of solution. This could be the reason for the observed lack of increase in cytotoxicity at 100 µM compared with 50 µM.
In agreement with our in vitro studies using celecoxib, we found that the microparticulate system of celecoxib used in this study was effective in reducing retinal VEGF protein levels. The reduction of the bloodretinal barrier breakdown can be partly explained by the reduction in the retinal VEGF expression. Several lines of evidence suggest an important role for VEGF in the breakdown of the bloodretinal barrier.15 57 68 It is a potent vasopermeabilizing agent,69 70 71 with efficacy 4 to 5 orders of magnitude higher than histamine.72 How hyperglycemia leads to increased VEGF is still open to investigation. There is some evidence of direct elevation of VEGF by hyperglycemia in culture systems. However, the major stimuli are considered to be inflammatory cytokines and oxidative stress that is generated due to the hyperglycemia. Our present and previous studies demonstrate that the celecoxib or celecoxib-PLGA microparticulate systems do not have an effect on the hyperglycemia or body weights in rats.10 Thus, reduction in VEGF is an outcome of other mechanisms. These could involve a reduction in the production of inflammatory prostaglandins, which is a direct consequence of the Cox-2 inhibitory effect of celecoxib. PGE2, a major prostaglandin produced by the Cox enzyme is known to stimulate VEGF in several cancer cells as well as in certain normal cells, including the retina.16 17 18 19 20 21 22 In addition, PGE2 has a direct effect on vascular permeability and can cause a breakdown of the bloodretinal barrier in rats and rabbits.8 73 74 In addition, studies from our laboratory have demonstrated that celecoxib can cause a reduction in diabetes-induced retinal oxidative stress.31 Thus, multiple pathways could be involved in the inhibition of VEGF by celecoxib. A recent important discovery of antiangiogenic isoforms of VEGF has brought to light a reason for possible failure of long-term anti-VEGF therapies.75 It is hypothesized that these antiangiogenic isoforms of VEGF may be inhibited by anti-VEGF therapies.75 76 77 If celecoxib inhibits antiangiogenic isoforms of VEGF, it could be a potential limitation of this drug. However, the present study demonstrated a 60% inhibition in PGE2, a 40% inhibition in VEGF, and a 40% to 50% inhibition of vascular leakage. Thus, the inhibition of vascular leakage might be due to the inhibition of VEGF and other possible pathways, including the direct vasopermeability effect of PGE2. Our studies to date suggest that, in diabetic conditions, the Cox-2 expression and activity, oxidative stress, VEGF expression, and vascular leakage are elevated (Fig. 8) and that all these parameters except Cox-2 expression can be reduced by celecoxib, a Cox-2 inhibitor.
|
Safety is an important concern with any new dosage form. The safety of periocular microparticles of biodegradable polymers has not been extensively investigated. Saishin et al.43 observed that microparticles of PLGA-glucose containing PKC412, a protein kinase C inhibitor, or blank PLGA-glucose microparticles did not cause any discernible signs of infection or inflammation in the conjunctiva 20 days after periocular administration of the microspheres in pigs. Kimura et al.,78 have evaluated the effects of periocular PLA microparticles on retina and surrounding tissues in a rabbit model. At 1 week after administration, they observed a few inflammatory cells and some fibrous tissue at the site of administration. At the injection site, the microspheres were degraded and phagocytosed by several multinucleated giant cells. The inflammatory reaction lasted for approximately 2 weeks, and at 12 weeks after administration, there were pieces of microparticles at the site of administration along with few inflammatory cells. However, the retina and the ciliary body were found to be normal on histopathologic examination. We observed no inflammation in the retina at 60 days after administration of the celecoxib-PLGA microparticles, indicating that the approach is safe without any cytotoxic damage to the retina. This was confirmed by our morphometric analyses, which showed no differences in the thickness of the retinal layers between untreated normal rats and normal rats injected with celecoxib microparticles. We have reported that, at 2 months after periocular injection in rats, nonbiodegradable polystyrene microparticles (2 µm) and nanoparticles (200 nm) are almost completely retained at the site of administration, whereas 20-nm particles disappear completely.32 With the polystyrene particles, we observed a few inflammatory cells in the periocular tissue, but not in the retina or other ocular tissues at the end of 2 months.32 However, with the biodegradable microparticles used in the present study, we did not observe any inflammatory cells or fibrous tissue response in the periocular tissue at the site of injection. Although no quantitative comparison of the inflammatory response can be made between the polystyrene and PLGA particles in these studies, the inflammatory response appears less for the PLGA particles, possibly due to the biodegradable nature of PLGA. Also, we observed that polystyrene particles have a greater tendency to aggregate in vivo, potentially influencing their clearance and inflammatory response. Further, celecoxib-PLGA particles did not induce systemic toxicity, as evidenced by no changes in blood cell counts or the clinical chemistry parameters in the plasma (Table 2) .
This study demonstrated that a microparticulate system of celecoxib can be used periocularly for therapy in early background diabetic retinopathy. Potentially, such particulate systems can be used for the therapy of other disorders of the posterior segment. Even with the present controversy, celecoxib could be beneficial in the treatment of diabetic retinopathy if we use local routes to minimize plasma concentrations. The efficacy, however, must be shown on a long-term basis, with no toxicity. Future studies thus should be designed to evaluate the efficacy of celecoxib in the actual lesions of diabetic retinopathy (pericyte loss, microaneurysms) and to investigate its use in proliferative diabetic retinopathy. This involves administration of celecoxib after the disease has set in and not the chemopreventive approach used in the present study.
| Conclusions |
|---|
|
|
|---|
| Acknowledgements |
|---|
| Footnotes |
|---|
Submitted for publication April 28, 2005; revised October 28 and November 27, 2005; accepted January 23, 2006.
Disclosure: A.C. Amrite, None; S.P. Ayalasomayajula, Novartis Pharmaceuticals (E); N.P.S. Cheruvu, None; U.B. Kompella, None
The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C.
1734 solely to indicate this fact.
Corresponding author: Uday B. Kompella, 985840 Nebraska Medical Center, Omaha, NE 68198-5840; ukompell{at}unmc.edu.
| References |
|---|
|
|
|---|