1From the Department of Ophthalmology, Hamilton Eye Institute, and the 7Department of Preventive Medicine, University of Tennessee Health Science Center (UTHSC), Memphis, Tennessee; the 2Department of Ophthalmology, University of Cagliari, Cagliari, Italy; the 4Jean Mayer USDA Human Nutrition Research Center on Aging, Tufts University, Boston, Massachusetts; the 6Department of Epidemiology and Biostatistics, University of California at San Francisco, San Francisco, California; the 5National Institute on Aging, National Institutes of Health, Bethesda, Maryland; and the 8Sticht Center on Aging, Wake Forest University School of Medicine, Winston-Salem, North Carolina.
| Abstract |
|---|
|
|
|---|
METHODS. MPOD was estimated with a heterochromatic flicker photometry (HFP) method in a large biracial population sample of normal 79.1 ± 3.2-year-old adults living in the Midsouth (n = 222; 52% female; 23% black, 34% users of lutein-containing supplements). Within a modified testing protocol, subjects identified the lowest and the highest target intensity at which the flicker sensation disappeared, and the exact middle of this "no-flicker zone" was interpolated by the examiner.
RESULTS. An MPOD estimate was obtained successfully in 82% of the participants. The mean MPOD in our sample was 0.34 ± 0.21 (SD). The interocular correlation was high (Pearsons r = 0.82). Compared with lutein supplement users, mean MPOD was 21% lower in nonusers (P = 0.013). MPOD was also 41% lower in blacks than in whites (P = 0.0002), even after adjustment for lutein supplement use. There were no differences in MPOD by gender, iris color, or history of smoking.
CONCLUSIONS. Older adults in the Midsouth appear to have average MPOD and interocular correlation comparable to those in previous studies. Lutein supplement use and white race correlated with higher MPOD. No evidence of an age-related decline in MPOD was seen in the sample. The HFP method for the measurement of MPOD is feasible in epidemiologic investigations of the elderly, the group at highest risk of ARM.
During the past 10 years, several noninvasive methods have been developed to quantify macular MPs in vivo. The bases and applications of these methods have been reviewed recently.17 18 19 20 21 The most commonly and most extensively validated method used is a psychophysical test based on heterochromatic flicker photometry (HFP).17 22 Subjects taking the test with this technique are asked to find the point at which the sensation of flicker in test targets disappears. The range of intensity within which flicker is no longer appreciated is termed the "no-flicker zone." Ordinarily, the subject is asked to identify empirically the middle of the no-flicker zone with progressively finer adjustments of the knob and to push a button at the subjectively determined point.
Several studies have reported the characteristics and correlates of MPOD measured with the HFP-based method in distinct American and European population samples, most of which focused on young to middle-aged adults.2 17 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 Of the few studies that involved older subjects,29 31 35 37 42 43 only that of Snodderly et al.42 focused on methodological issues and challenges pertaining to MPOD testing in the elderly, reporting highly reproducible results within a median time of 45 minutes to test both eyes. Herein, we illustrate our findings in a large sample of elderly individuals from the Midsouth with a simpler protocol modified for use in geriatric populations in an epidemiologic setting.
| Methods |
|---|
|
|
|---|
All participants were free of diabetic retinopathy and glaucoma or any other overt retinal and/or optic nerve disease (as determined by history, clinical examination, or both) that may confound or otherwise affect MPOD determinations. Subjects with unilateral conditions such as macular hole or amblyopia were allowed to participate as long as the fellow eye met the inclusion criteria. All participants underwent detailed eye examinations, including documentation of lens opacity based on published AREDS (Age-Related Eye Disease Study) criteria,47 iris color (categorized as blue-gray, green, hazel, brown, or black), and stereo fundus photography of the macula. Photographs were obtained and graded in a masked fashion according to the published AREDS criteria.48 Only elderly subjects free of ARM by both clinical and masked fundus photograph grading criteria are included in this report. The resultant study sample included 222 subjects, 52% of which were women and 23% of which were black. Only six of the participants were active smokers, whereas 101 were previous smokers and 113 had never smoked. Smoking information was not available for one subject. Information was also collected about current use of dietary supplements containing lutein. This information could be verified in all but one participant by either direct inspection of the bottle of dietary supplements used by the participants (typically a multivitamin enriched with lutein), or by obtaining the name and brand of the supplement at the time of examination and verifying subsequently if it contained lutein supplements. Use of lutein-containing supplements (n = 75) ranged between 0.25 mg/daily (the dosage currently found in most multivitamin supplements) and 20 mg/daily. Additional details on the characteristics of the resulting study sample are summarized in Table 1 . All procedures conformed to the Declaration of Helsinki and were approved by the Institutional Review Board of the University of Tennessee Health Science Center (UTHSC).
|
The ratio between measurements for a 1.0° foveal target (i.e., providing information on MPOD at 0.5° eccentricity) and one obtained parafoveally with a 2° diameter stimulus centered approximately 7° from fixation (where the MP density is minimal) provided an estimate of the MPOD in our study. The 1.0° foveal target is the one that has been most often used in previous studies. Fixation for the foveal target was maintained via a 5-minute spot in the middle of the test target. For the parafoveal estimates, a small, red LED, always situated to the left of the background field, was used as an eccentric fixation device. The flicker frequency of the two test stimuli was always >8 Hz foveally and >5 Hz parafoveally and was optimized by the examiner for each subject and for each stimulus (typically, between 9 and 13 Hz for the foveal stimulus and between 6 and 10 Hz for the parafoveal stimulus). Only subjects with corrected visual acuity of 20/100 or better in at least one eye to ETDRS (Early Treatment Diabetic Retinopathy Study) chart testing were considered eligible to attempt MPOD determinations. All subjects were tested with the correction at near that allowed them the sharpest resolution of a ring test target. Both positive and negative additions to the default +1.50-D lens of the instrument were allowed.
To minimize the variability of test results and participants fatigue, a slightly modified testing protocol was used. Participants were instructed to identify the limits of the no-flicker zone for each target, which were termed the "minimum" and the "maximum" intensities for the test target in question. They performed the test by adjusting, first clockwise and then counterclockwise, a knob controlling the intensity of the test targets (see Fig. S1 in the Online Appendix, available at http://www.iovs.org/cgi/content/full/48/4/1458/DC1, for further details), going always from flickering to not flickering and starting at the low-intensity end (i.e., minimums first). Participants were always encouraged to blink several times when they first thought they had reached a no-flicker point and to continue adjusting the knob until the blinking no longer allowed the sensation of flickering in the test targets to resume. The examiner then calculated the exact mathematical average of the minimum and maximum numerical values, which identified the middle of the no-flicker zone, and entered it on behalf of all subjects. For participants who had difficulty adjusting the knob on their own (e.g., in case of tremor), the examiner performed the task on their behalf, instructing the subject to notify the examiner immediately upon cessation of the flicker sensation. A similar strategy recently has been used successfully by others.49 50 As detailed in the Online Appendix, with this protocol, we could limit test repetitions to three, instead of the five to eight used in previous studies, attaining equally accurate estimates more rapidly.
Statistical Methods
Frequency distributions and other basic information were obtained in a spreadsheet program (Excel; Microsoft, Redmond, WA). All other statistical analyses were performed with another commercial program (SAS statistical software, ver. 8.1; SAS, Cary, NC). Unless otherwise specified, all analyses were conducted on a per-subject basis (i.e., averaging the MPOD estimates between the two eyes). For participants who could contribute an MPOD estimate from only one eye, the value from that eye was used. To determine whether there was a significant difference in the characteristics of participant subgroups, a two-tailed paired Students t-test was used for continuous variables (e.g., MPOD) and the
2 test was used, or the odds ratio (OR) was calculated, for dichotomous variables, as appropriate (e.g., MPOD estimate obtained versus not obtained). Correlations between continuous variables (e.g., between-eye MPOD) were approached with a general linear model and characterized by means of the Pearsons correlation coefficient (r). When appropriate, other potential confounding variables were included in and controlled for in the model. Furthermore, comparisons between multiple subgroups (e.g., by iris color) were analyzed by analysis of variance (ANOVA) and of covariance (ANCOVA), as appropriate. Preplanned analyses included the estimation of the MPOD interocular correlation; comparison of MPOD estimates between genders (male versus female), races (white versus black), lutein use (lutein supplement users versus non-users), and iris colors; and the correlation between MPOD and age. Because of the multiple additional comparisons performed in this study, we conservatively considered P < 0.01 to be statistically significant for all comparisons.
| Results |
|---|
|
|
|---|
|
The duration of an entire testing session, from the time that subjects entered the testing room to the time they exited it, was documented in 157 instances. On average, a session lasted nearly 52 minutes. Of this time, active testing with our protocol was 20 ± 9 minutes per eye (95% CI: 18.521.4 minutes per eye). Therefore, when both eyes were eligible for testing, the average subject would require approximately 35 to 40 minutes of active testing to attain an MPOD estimate in both eyes.
Significant MPOD Differences by Lutein Supplement Use and Race, but Not between Genders or by Iris Color
Table 3 details the main findings in the 183 subjects from the Midsouth who were eligible for retention and in whom an MPOD estimate was obtained in at least one eye. The mean MPOD in our study sample was 0.34 ± 0.21. As expected, the MPOD in the right eyes correlated highly with that of the left eyes (Pearsons r = 0.82; P < 0.0001). Consistent with its expected biological correlation, the overall mean MPOD was higher (two-tailed unpaired Students t-test, P = 0.013) in lutein supplement users (0.39 ± 0.20) than in nonusers (0.31 ± 0.21). Furthermore, low-dose users (
0.5 mg/daily; n = 55) had an MPOD of 0.38 ± 0.20, and high-dose users (
2 mg/daily; n = 7) had an MPOD of 0.51 ± 0.17. This pattern was observed consistently in both males and females and in white and black subjects (not shown). The frequency distribution of these estimates by lutein supplement use is illustrated in Figure 1 . Users of lutein had a substantially higher proportion of subjects in the 0.51 to 0.70 MPOD range than did nonusers (27% vs. 12.5%), who outnumbered users in the 0.00 to 0.20 MPOD range (33% vs. 14.5%).
|
|
|
We also investigated the relationship between MPOD and iris color. Blue-gray irises were defined as group 1 (n = 69). Because there were too few subjects with green irises, they were grouped with those with hazel ireses (group 2, n = 66), as in Hammond et al.26 Subjects with brown irises were categorized as group 3 (n = 48). No subject was classified as having black irises. An initial unadjusted comparison of the MPOD showed a significant difference between the three groups, but the MPOD-iris color relationship in our sample was confounded by the black subjects in our sample being clearly overrepresented in group 3 and by the fact that there were very few lutein-containing supplement users among the blacks. When multivariate analyses were conducted also including race and lutein supplement use, iris color was no longer associated with significant differences in MPOD. When MPOD comparisons by iris color were repeated only for white nonusers (n = 92), we still found no significant difference between the three subgroups, but the few white subjects with brown irises had the highest mean MPOD estimates of the three groups (group 1: 0.35 ± 0.19, n = 44; group 2: 0.32 ± 0.18, n = 40; group 3: 0.37 ± 0.20, n = 8). This trend is in line with a previous report of higher MPOD in subjects with dark irises.26
MPOD in the Elderly: No Relationship with Past Smoking or Age
It has been shown that active smoking correlates with lower MPOD levels.25 51 There were too few active smokers (n = 6, four of whom had MPOD estimates) in our sample to investigate this relationship. When contrasting MPOD in past smokers (n = 81) versus never smokers (n = 92), MPOD tended to be lower in the former (0.31 ± 0.21 vs. 0.37 ± 0.21). However, also this modest nonsignificant trend was further reduced once race and lutein-containing supplement use were controlled for in multivariate analyses (least-square MPOD means: past smokers = 0.30; never smokers = 0.33).
Last, we investigated the relationship between MPOD and age. Over the two-decade span in which estimates were successfully obtained in our population sample (range, 6986 years), MPOD displayed only a very small, nonsignificant age-related decline (Pearsons r = 0.026, P > 0.05). This overall trend did not change, even after adjustment for lutein supplement use, gender, race, and iris color.
| Discussion |
|---|
|
|
|---|
Feasibility of MPOD Testing in the Elderly in a Large-Scale Epidemiologic Setting
With our simplified protocol, we successfully obtained bilateral MPOD estimates over the entire age range examined in 71% of the participants and in at least one eye of 82% of them. Measurements were usually completed within a reasonable length of time (18.521.4 minutes/eye, 95% confidence interval [CI]) for the 1° target. Taking into account the characteristics of our study sample, this testing time compares reasonably well with that of 45 minutes reported by Snodderly et al.42 in their substantially younger, white, highly educated female participants. Although theoretically ideal, obtaining estimates at additional loci may prove impractical and unattainable, at least bilaterally, in a large-scale investigation of the elderly. Disadvantages of excessively prolonged testing would include increased fatigue, possible loss of reliability and, potentially, a substantial increase in the attrition rate. Depending on the studys purpose and the retinal health status of the population of interest, single-target binocular estimates and/or multiple-target monocular MPOD profiling may be preferable.
MPOD in the ARMA Study Sample: Comparison to Previous Studies
Table 4 illustrates a comparison of our findings with previous studies with the HFP-based technique conducted in other U.S. populations.23 24 25 26 27 28 29 31 32 33 34 35 37 38 39 41 42 43 All the investigations included in Table 4 were performed with 1° stimuli at the same peak wavelength of 460 nm used in our study, as well as studies that conducted parafoveal measurements at 4° eccentricity. For these studies, based on Robson et al.,52 it is possible that the use of a 4° parafoveal target underestimated the MPOD by approximately 10%, and possibly by as much as 20%. A reference location at approximately 7° like the one used in the present study and that of Snodderly et al.42 has been deemed the most appropriate.52 With these caveats in mind, the observed MPOD in our sample (0.34 ± 0.21) was identical with the mean of all listed studies combined (0.34 ± 0.11; range: 0.190.57). Compared with the average MPOD reported in other groups of elderly subjects,29 31 35 37 42 43 our subjects were again within the reported range (0.210.57).
|
2 mg/daily; n = 7) had estimates that were, on average, 25% higher than those in low-dose supplement users (
0.5 mg/daily; n = 55). Although our data do not provide direct proof that this difference is due to consumption of these supplements and not to, for example, differences in dietary habits preexisting the use of supplements or other factors, these results are biologically plausible and, consistent with those in previous reports,28 30 35 44 53 they support the possibility that consumption of lutein-enriched dietary supplements may result in higher MPOD levels in elderly individuals. The putative eyesight protective and ARM-preventing effects of this MPOD enhancement remain, of course, to be verified in forthcoming controlled double-blinded prospective trials.
MPOD in Elderly Blacks versus Whites in the Midsouth
Published data on MPOD in blacks are few. In studies of a Midwestern population sample,33 38 39 32 of 280 participants were black. In this sample, the MPOD in the blacks was slightly higher than that in the whites. Unlike in these studies, we observed higher MPODs in whites, a finding that is in line with an earlier study by Hammond et al.26 In our sample, the difference between the two race-based groups was highly significant, even when comparisons were limited to non-lutein-supplement users. The prevalence and incidence of ARM in the black populations studied to date is far lower than that in whites, and yet data are scarce because of the small number of black participants.54 Therefore, additional studies of elderly black populations appear to be necessary, to characterize their MPOD features further, identify their correlates, understand whether the correlates may be different from those in whites, and whether any of these putative differences may explain, at least in part, the lower prevalence of ARM among blacks.
No Difference in MPOD by Gender, Iris Color, or Past Smoking
In previous investigations over a wide age range, women had or tended to have lower MPOD levels than did men.27 33 34 38 39 With an HFP-based method but different stimuli, Mellerio et al.51 also observed a significantly higher MPOD in U.K. men. In contrast, in a study conducted on New England subjects by Johnson et al.,35 the women had, on average, higher MPOD than did the men. Our study results differ from most studies of younger subjects,27 33 34 38 39 51 but are consistent with that of Johnson et al.,35 a portion of whose study participants were older than in the other studies (see Table 4 ). Taken together, these findings suggest that intergender differences in MPOD, if any, may vary between populations and may differ depending on the age range sampled and that female gender alone, at least in elderly subjects, does not intrinsically predispose to or otherwise correlate with lower MPOD levels. This conclusion is supported also by previous investigations.35 45
Similar to the effect of gender, iris color in our sample of elderly individuals did not display the same significant correlation with MPOD observed in earlier studies that included mainly much younger subjects.26 38 51 Studies of larger elderly white samples with a sufficient number of subjects with dark irises are needed to determine whether the previously reported higher MPOD in younger adults with dark iris color is also present in the elderly.
Smoking is a modifiable lifestyle habit that is the leading environmental risk factor for ARM55 and a significant independent determinant of serum levels of lutein and zeaxanthin, despite high dietary intakes.56 However, past smokers do not have lower serum lutein and zeaxanthin levels that never smokers.56 The effect of smoking on MPOD has been investigated before in younger samples,25 51 showing lower MPOD estimates in smokers and an inverse relationship of MPOD with the number of cigarettes smoked daily. Consistent with results of studies at the serum level,56 our investigation provides no immediate evidence that being a past smoker is associated with lower lutein and zeaxanthin at the retinal level in elderly subjects. It remains to be determined whether reduced MPOD is also present in actively smoking elderly subjects.
Lack of an Age-Related Decline in MPOD in Elderly Midsoutherners
The data summarized in Table 4 provide no evidence of an age-related decline in MPOD across populations, which is consistent with the results of other investigators.43 46 51 This, along with our observed lack of any age-related decline in MPOD within our study sample, suggests that there seems to be little evidence of an age-related decline in MPOD at 0.5° of eccentricity from fixation with the HFP-based technique.
It must be noted that, except for the studies of Ciulla and Hammond43 and Snodderly et al.,42 most previous studies included only a limited number of elderly subjects and that in the previous studies in which age-related changes in MPOD was investigated,43 46 51 information on use of lutein- and/or zeaxanthin-containing supplements was not obtained or, even when available, information on dietary patterns was not included in the age analysis.51 Therefore, one cannot exclude that unaccounted for use of such supplements and/or dietary factors may have exerted a confounding effect in these as well as other studies, erasing any age-related effect. However, this was not the case in our study.
An inverse correlation between MPOD and age has been observed by Bernstein et al.,57 by means of a Raman spectroscopy-based technique. It is possible that the lack of age-related decline observed with HFP-based techniques may result from methodological differences with Raman spectroscopy,57 58 as further debated extensively elsewhere.59 60 61 62 The MPOD age-related decline observed with the Raman technique may be the result of interference from media opacities,43 or, since this method averages MP density up to approximately 1.7° of eccentricity,57 58 it may also be due to preferential MP density losses farther away from the foveola than that sampled by a 0.5° target. The latter explanation would be in line with the clinical observation of foveolar resiliency in geographic atrophy.63 64 65 66 67
| Conclusions |
|---|
|
|
|---|
| Acknowledgements |
|---|
| Footnotes |
|---|
Supported by National Eye Institute Grant K23 EY000409; National Institute on Aging (NIA) Contracts N01 AG62101, N01 AG62103, and N01 AG62106 and the Intramural NIA Research Program; the International Retinal Research Foundation, Birmingham, AL; Macular Degeneration Research, American Health Assistance Foundation, Clarksburg, MD; and a Career Development Award (AI) and an unrestricted grant to the UTHSC Department of Ophthalmology from Research to Prevent Blindness. KTG was the recipient of an intramural Medical Student Summer Research Fellowship, supported by National Institute of Diabetes and Digestive and Kidney Diseases training Grant T35 DK07405 (UTHSC). TLH was the recipient of a Memphis McNair Program Summer Research Fellowship, supported by a grant from the US Department of Education P217A030229 to UTHSC. The MacularMetrics instrument utilized to measure macular pigment optical density in this study was purchased with the generous joint funding of Bausch & Lomb and Kemin Foods Corp.
Presented in part at the annual meeting of the Association for Research in Vision and Ophthalmology, Fort Lauderdale, Florida, May 2005.
Submitted for publication April 18; revised August 7, September 12, and October 10, 2006; accepted January 24, 2007.
Disclosure: A. Iannaccone, Bausch & Lomb (F), Kemin Foods (F); M. Mura, None; K.T. Gallaher, None; E.J. Johnson, None; W.A. Todd, None; E. Kenyon, None; T.L. Harris, None; T. Harris, None; S. Satterfield, None; K.C. Johnson, None; S.B. Kritchevsky, None
The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C.
1734 solely to indicate this fact.
Corresponding author: Alessandro Iannaccone, Department of Ophthalmology, Hamilton Eye Institute, University of Tennessee Health Science Center, 930 Madison Avenue, Suite 731, Memphis, TN 38163; iannacca{at}utmem.edu.
| References |
|---|
|
|
|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |