|
|
||||||||
1From the Ocular Surface Group, Institute of Applied Ophthalmo-Biology (IOBA), the 2School of Architecture, and the 3Department of Statistics and Operative Research, University of Valladolid, Valladolid, Spain; and the 4Divison of Biological Sciences, Allergan, Inc., Irvine, California.
| Abstract |
|---|
|
|
|---|
METHODS. Ten minimally symptomatic contact lens (CL)–wearing subjects were exposed, without (WO-) and with (W-)CLs, to a controlled adverse environment (CAE) of 22.0 ± 2.0°C and 19.0% ± 4.0% relative humidity (RH) for 2 hours in an environmental chamber (EC). One month later, the same subjects were placed in an indoor normal environment (INE) of 24.2 ± 1.3°C and 34.8% ± 2.9% RH for 2 hours. DE-related signs and symptoms were evaluated before and after each exposure. The reversibility of changes provoked by CAE or INE was also evaluated.
RESULTS. Without CL wear, significant changes were found in DE signs (noninvasive tear break-up time [NIBUT], conjunctival hyperemia and phenol red thread test) after CAE exposure, but not found after INE exposure. However with CL wear, the same tests were altered after both CAE and INE exposure. Most of these changes returned to normal values within 1 month after environmental exposure.
CONCLUSIONS. Significant changes in comfort and the ocular surface tests were found after 2 hours of exposure to CAE. These results show the negative impact that an adverse environment, especially low RH, can have on the ocular surface. These alterations were fully reversible. This indicates that the CAE is a safe and functional condition in which to standardize DE diagnostic tests and evaluate therapeutics.
To understand the way that environment affects the ocular surface and provokes signs and symptoms of DE, it is necessary to control exposure conditions such as humidity, temperature, air flow, and pollutants. Environmental chambers (ECs) have been used to create controlled environments to evaluate subject responses to a determined stimulus. An example is the assessment of antiallergic drug effectiveness in subjects exposed to a controlled allergen charge.7 8 9 Studies that show the influence on the ocular surface of irritating factors such as cigarette smoke,10 dust,11 or topically instilled topical drugs12 have also been performed in ECs.
Controlled adverse environments (CAEs) created with ECs have been used to develop animal models of DE.13 14 CAEs can improve the design of clinical trials and have been used to study the effects of DE therapeutics1 15 and to evaluate the effect of contact lens (CL) wear on the ocular surface.16 17
The purpose of this study was threefold. First, we determined whether a CAE adversely affects the normal-to-borderline ocular surface of young, healthy persons with symptoms induced by CL wear. Second, we evaluated the possible negative impact of CL wear in a CAE. Third, we determined whether the alterations of the ocular surface were reversed after cessation of adverse environment exposure. The results from the CAE were then compared to results of similar exposure of the same subjects to an indoor normal environment (INE).
| Materials and Methods |
|---|
|
|
|---|
The nature of the research and protocols was explained to the subjects before written informed consent was obtained during the screening visit. The study complied with the tenets of the Declaration of Helsinki, and the protocol was approved by the Institutional Review Board of the University of Valladolid.
Environmental Conditions
Subjects were exposed to two different environment conditions that differed principally in relative humidity (RH).
Controlled Adverse Environment.
Individuals were subjected to a controlled adverse environment (CAE) in an EC located in the Environmental Laboratory (School of Architecture, University of Valladolid). The EC is an isolated room 4.6 m wide, 5.8 m deep, and 2.5 m high. Two of the walls and the roof of the EC are made of plaster board. The other two walls are made of double-paned windows, to facilitate observing the interior of the chamber from the outside. The floor is made of wood covered with linoleum. The EC was equipped with a closed air circulation system consisting of a circular duct with propellant and return vents. Temperature and RH could be precisely controlled between 20°C and 30°C and RH from 15% to 80%, with a 10% tolerance. For temperature control, the EC air conditioning system (SDH 105, TD Saunier-Duval; Valliant, Remscheid, Germany) had a cooling capacity of 10.20 kW and a heating capacity of 11.6 kW. The RH was reduced by using the indoor coil of the air conditioning system to condense the water vapor in the air. A more stable control of RH was achieved with a 1.13-kW and 1.5-kg/h humidifier (Humisteam UE001PD000; Carel, Padova, Italy). Control the EC conditions was carefully supervised during the entire duration of the experiments, with two portable devices used to measure temperature and humidity (635 and 645; Testo, Lenzkirch, Germany) located inside the EC. For this study, the temperature was set at 22°C and the RH was 20%. The temperature and RH were recorded at the beginning, in the middle, and at the end of each experiment, and the mean values (± SEM) were 22.0 ± 2.0°C and 19.0% ± 4.0%, respectively. There was no air flow, and the subjects read throughout each experiment, so that they were constantly engaged in visual activity. They were exposed to these conditions for 2 hours. We chose these conditions based on studies reported in abstract form (Ousler GW et al. IOVS 2004;45:ARVO E-Abstract 80; Kellerman DJ et al. IOVS 2004;45:ARVO E-Abstract 3892) which had a CAE of RH <10% for 90 minutes. We chose a less extreme, more commonly experienced RH of 20%, and a duration of 2 hours.
Indoor Normal Environment.
Four weeks after exposure to a CAE, individuals were subjected to an indoor normal environment (INE). This real-life environment was located in a room in one of the University libraries. For 2 hours, the subjects did the same kind of reading activity as during the CAE exposure. The temperature and RH were measured at two different places inside the room with a weather station (EMR812GHN; Oregon Scientific, Tualatin, OR) at 9 AM, 1 PM, and 6 PM. The mean temperature and RH were 24.2 ± 1.3°C and 34.8% ± 2.9%, respectively. As the whole experiment was held during winter, the environment in the library was artificially heated and had no air flow.
Tests Performed
The following examinations were performed in the following sequence and as outlined in Table 1 .
|
Noninvasive Tear Break-Up Time.
A device for assessing tear film (Tearscope Plus; Keeler, Windsor, UK) was used to measure noninvasive tear break-up time (NIBUT). The mean of three measurements was recorded,26 and times of 10 seconds or less were considered abnormal.27
Bulbar and Limbal Conjunctival Hyperemia.
Bulbar conjunctival and limbal hyperemia were evaluated with a slit lamp (SL-8Z; Topcon Corp., Tokyo, Japan) on a 0.1 decimalized scale (range, 0–4).19 Redness of 2.6 or greater was considered abnormal.28
Phenol Red Thread Test.
The phenol red thread test (Zone Quick Test; Menicon Ca, Ltd., Nagoya, Japan) was placed in the recommended position over the lateral canthus and read 15 seconds after placement.29 Values of 20 mm or below were considered abnormal.30
Tear Break-up Time.
For tear break-up time (T-BUT) measurements, fluorescein strips previously wetted with 0.9% sodium chloride (NaCl 0.9% 10 mL; B/Braun, Barcelona, Spain) were gently applied to the inferior fornix. T-BUT was measured after three blinks, and the mean of three measurements was recorded.31 Values of 10 seconds or below were considered abnormal.18
Corneal and Conjunctival Vital Staining.
Corneal fluorescein staining was evaluated with fluorescein strips (Fluorets; Chauvin, Aubenas, France). After they were wetted with 0.9% sodium chloride, they were gently applied to the inferior fornix. The cornea was divided into five regions (central, superior, inferior, nasal, and temporal), and each region was graded on a 0.1 decimalized scale (range, 0–4).19 The scores of each area were added to arrive at a final grade. Evaluation of conjunctival staining was similarly scored,19 except that it was divided in four regions (superior, inferior, nasal, and temporal).
For rose bengal conjunctival staining, rose bengal strips (Akorn, Inc., Buffalo Grove, IL) were wetted with one drop of 0.9% sodium chloride and gently applied to the inferior fornix. For grading, the Oxford scheme was used.20 Rose bengal staining was used only during the screening visit, to avoid interference with the CLs that had to be inserted in some of the visits. Any staining with fluorescein or rose bengal was considered abnormal.
Tear Lysozyme Concentration.
This test was chosen as a marker of aqueous-deficient DE22 and is routinely performed in the clinical units of our institution. Sampling of tears was taken by gently applying a 5-mm diameter filter paper disc in the inferior conjunctival cul-de-sac of both eyes for 1 minute with eyes closed. Samples were kept at –20°C until processed. To determine tear lysozyme concentration, the Micrococcus lysodeikticus (ATCC 4698, M3770; Sigma-Aldrich, St. Louis, MO) agar diffusion assay32 in Mueller Hinton agar plates (Bio Merieux, Marcy l'Etoile, France) was used. Each filter paper was left in the plate with the Micrococcus lysodeikticus (inocula was 2 x 106 CFU/mL) suspension gel, and the inhibition hallus was measured after 24 hours. To calculate the lysozyme concentration, a standard curve was obtained by using the same disks wetted with 10,000, 1,000, 100, and 10 µg/mL of lysozyme (ATCC 4698, L6876; Sigma-Aldrich) diluted in phosphate-buffered saline (Invitrogen Corp., Carlsbad, CA). Values of 1000 µg/mL or below were considered abnormal.22 23
Schirmer Test.
One drop of topical anesthetic (0.5% tetracaine chlorhydrate and 0.5% oxybuprocaine chlorhydrate; Colircusí Anestésico Doble; Alcon-Cusí, Barcelona, Spain) was instilled in the inferior fornix. After 2 minutes, excess tears were removed by applying the tip of a tissue to the inferior cul-de-sac. One sterile strip (Schirmer Tear Test Strips, 5 x 35 mm; Alcon Laboratories, Inc., Fort Worth, TX) was placed in the lateral canthus of the inferior lid margin of both eyes,33 and the subjects were asked to maintain closed eyes during the test. The length of wetting was measured in millimeters after 5 minutes. Results of 5-mm length or less were considered abnormal.21
Study Protocol
Once enrolled in the study, each subject attended four visits (V1–V4) and 10 evaluations (E1–E10). Table 1 lists the tests performed at each visit and evaluation. The subjects were evaluated just before and after being exposed to the CAE (V1 and V2) or INE (V3 and V4). In both environments, they were evaluated without (WO-)CLs (V1 and V3) or with (W-)soft CLs (Focus Visitint, Vifilcon A, ionic, 55% water content; Ciba Vision, Duluth, GA) that were bilaterally fitted (V2 and V4). CL visits (V2 and V4) were performed 4 to 7 days after no-CL visits (V1 and V3, respectively), and INE visits (V3 and V4) took place 30 days after CAE visits (V1 and V2, respectively).
For V1 and V2 (CAE exposure), ocular examinations were performed at the Environmental Laboratory just beneath the entrance of the EC. For V3 and V4 (INE exposure), ocular examinations were performed at the IOBA clinical units, located near the library room used for exposing subjects to the INE. Subjects were asked to discontinue their CL use at least 24 hours before each visit. Tests were performed (E1, E3, E6, and E8; Table 1 ), and eyes were rinsed with 0.9% sodium chloride and left untouched for 30 minutes. For CL visits, immediately after rinsing, CLs were inserted, and after an interval of 30 minutes, some tests were performed (E4, E9, Table 1 ). Subjects then entered the controlled environment (CAE or INE) and remained inside for 2 hours. Immediately after exposure, subjects were again evaluated (E2, E5, E7, and E10; Table 1 ); examination was completed within 10 minutes of the end of the exposure. To study variations in perceptions of comfort, whereas inside the EC, each subject was asked to self-evaluate his or her comfort level after 1 hour of CAE exposure.
The sample size was established to detect differences below 2 seconds (over baseline conditions) in NIBUT and 3 mm in the Schirmer test. Toward this goal, information about variability of these tests,34 along with a hypothesis relative to the estimated gain in power due to the paired nature of this study design was used.
Statistical Analysis
Results are expressed as the mean ± SEM. The geometric mean was added for those variables in which log-transform was used (NIBUT and tear lysozyme concentration) with the intention of gaining interpretability by recovering the usual scale. The geometric mean is reorientated as emean[ln(x)].
When a test was performed in both eyes, the mean of the two measurements was used in the statistical analysis.
Among the available methods to analyze data, with some ordinal measures, the ones in the parametric family were chosen, due to the belief that all the variables measured in this study (in case of NIBUT and tear lysozyme concentration after log transform) supports the hypothesis: for three values x, y, and z, the change in magnitude between x and x + z is clinically comparable to the difference between y and y + z.
Assuming this hypothesis being true, it makes sense to add data from different subjects, and in this situation, a high-efficiency summary for the location of the observed values in the sample is the mean, and the SEM can be used as a measure of the estimated error.35 36 37 38 39 The use of this methodology necessarily assumes that the above mentioned hypothesis is true. In addition, parametric procedures for comparison of the means are quite robust with normality deviations, except when they are due to heavy tailed40 which is not the present case.
In the framework of a repeated-measures analysis, a multiple-comparison method based on Tukey's theory was applied, to test the difference between evaluations (E1–E10). The Mauchly test and epsilon estimate were performed to verify the sphericity condition. NIBUT and the tear lysozyme concentration met this condition after a logarithmic transformation was performed. For variables that appeared with evidence of a sphericity hypothesis violation, a separate variance estimation in a multiple-comparison procedure was used.
P
0.05 was considered to show statistical significance.
| Results |
|---|
|
|
|---|
Environmental Exposure–Induced Changes
Initial baseline values (E1, E3, E6, and E8) of all variables were within the clinically normal range. To evaluate the influence of exposure to the CAE or the INE, means of the variables evaluated before exposure (E1, E3, E6, and E8) and after exposure (E2, E5, E7, and E10) were compared (Table 2) .
|
|
Effect of Wearing CLs
To evaluate the effect of CL wear in CAE and INE conditions, differences between pre- and postevaluations without CL (CAE E2-E1 and INE E7-E6) were compared with differences between pre- and postvisits with CLs (CAE E5-E4 and INE E10-E9). NIBUT demonstrated a higher decrease without than with CLs in the CAE (difference not found in the INE), and the phenol red thread test showed a higher decrease with CLs than without them, in both CAE and INE situations (Table 2) .
Short- and Long-Term Recovery
The reversibility of changes provoked by CAE or INE exposure was studied, to evaluate the safety of the environmental conditions used. To do this, a short-term recovery was defined as the absence of significant changes 4 to 7 days after CAE exposure between E1 and E3 (CAE WO-CL) or after INE exposure between E6 and E8 (INE WO-CL). For CAE, long-term recovery (5 weeks) was defined as the absence of changes between E1 and E6 (CAE WO-CL) or E4 and E9 (CAE W-CL).
The short-term recovery analysis for CAE conditions without CLs (E1, E3; Table 2 ) showed that symptoms improved 4 to 7 days after exposure, and for INE conditions without CLs, limbal hyperemia significantly improved (E6, E8; Table 2 ). The long-term recovery analysis after CAE exposure also showed that ocular surface had almost completely returned to the previous values. Thus, 30 days after going through CAE, either with or without CL, values were similar or even better than at the outset. NIBUT and limbal hyperemia with CL improved significantly (E4, E9; Table 2 ).
| Discussion |
|---|
|
|
|---|
In this study, we evaluated the influence that variations in RH can have on the ocular surface of humans, maintaining nearly constant the other variables that can influence the results such as temperature, air flow, and visual tasks. Though the relationship is not exactly linear, RH levels vary inversely with temperature41 when water vapor remains constant. We analyzed the influence of 19.0% RH in the CAE and 34.8 RH in the INE on the ocular surface while maintaining similar temperature, 22.0°C for the CAE and 24.2°C for the INE. Thus, findings are mainly attributed to the differences in RH.
Morgan et al.17 found no changes in the dehydration of CL or comfort in subjects exposed to different RH and temperature levels. However, they used low levels of RH in conjunction with high temperatures (5% RH at 30°C) and high RH with low temperatures (90% RH at 5°C). Thus, their conditions were not comparable to ours. Maruyama et al.16 used low RH at low temperatures and high RH at high temperatures (10% RH at 5°C and 50% RH at 35°C). When the two variables were changed simultaneously, the effects of RH changes alone were unclear. Nevertheless, the changes they found in NIBUTs, interference patterns, and dryness symptoms support our findings that low RH increases DE signs and symptoms.
The subjective responses of individuals were evaluated with the comfort-based visual analog scale and the symptoms-based SODQ so as to avoid missing symptoms due to the difference in the way individuals express themselves. The results obtained in comfort and symptoms scores differed from one another. While comfort was decreased in the CAE with CLs, there were no changes in symptoms. These results can be explained in two ways. First, both tests evaluated different parts of the subjective response, as subjects may interpret words as "comfort" or "dryness" as different sensations. Second, comfort and symptoms were measured in different ways. Comfort was assessed with a 0-to-10 visual analog scale that was more sensitive than the 0-to-4 verbal scale used to assess symptoms.42 43 44
The fact that there was no significant decrease in comfort after 2 hours of CAE exposure without CLs could indicate that further studies with these conditions should be longer. However, comfort with CLs decreased during the first hour, indicating that this variable is more affected by CL wear; therefore, we conclude that studies with CLs could be of shorter duration.
NIBUT was performed to assess tear film stability instead of T-BUT used in the screening visit because it permitted us to evaluate tear film behavior on the surface of the CLs. Without CLs, tear film stability was negatively affected after 2 hours of CAE exposure, in agreement with other authors.2 45 46 Maruyama et al.16 observed no changes in NIBUT without CLs when subjects were exposed to CAE for 15 minutes. This short exposure probably explains the difference between their results and ours. In our study, NIBUT was not influenced when CLs were on. Thus, the CL may protect the ocular surface from external changes for a short period. Nilsson and Andersson47 found a decrease in T-BUT in CL wearers when RH was below 31% in working places and exposure times were longer than 2 hours. However, Maruyama et al.16 found a decrease in NIBUT when subjects were exposed to low RH when wearing CLs. More work is needed to clarify this discrepancy.
Both limbal hyperemia and conjunctival fluorescein staining increased secondary to exposure to the CAE without CLs, indicating that the ocular surface was altered during the adverse conditions. With CL wear, both the CAE and the INE induced conjunctival hyperemia. Increases in limbal redness has also been found by other investigators,48 49 and it has been attributed to the local hypoxia that can be induced on the limbal conjunctiva by the edge of the CLs.
Although the Schirmer and tear lysozyme concentration tests are good to evaluate tear production, we did not find any variation with CAE or INE exposure. Possibly the exposure time was too short to show any change in normal-to-borderline subjects; however, there are inconsistent results in the literature related to Schirmer variations in adverse environments. Paschides et al.46 found a decrease in Schirmer results in subjects living in cities with dry climates; however Muzi et al.2 did not find any difference in subjects working in so-called sick buildings, defined as air-conditioned buildings in which employees had a high prevalence of irritative symptoms involving the eye and respiratory tract compared with that of subjects working in so-called healthy buildings. Another reason for our findings is that we studied nearly normal subjects. DE subjects can be more affected by CAE, as others have found.15 The phenol red thread test was the only measure of production that changed after environmental exposure. It decreased in the CAE without CLs, but not in the INE, perhaps because the phenol red thread test is less invasive29 and detected more subtle changes than did the Schirmer test or tear lysozyme concentration tests. With CL wear, the phenol red thread test decreased in the INE, indicating that the presence of CL in some way alters tear production in a similar way that CAE does.
In general, we found that the CAE affects more negatively a normal-to-borderline ocular surface than the INE. McCulley et al.50 found that a decrease in RH results in an increase in tear evaporation. The low RH to which subjects were exposed during CAE in our study could have provoked an increase in tear evaporation that led to the changes in signs and symptoms that we observed. Although this possibility seems likely in our experimental conditions, we did not actually measure tear evaporation.
CAE conditions seemed to affect the ocular surface more negatively when no CLs were worn compared with INE conditions in which no change in any variable occurred. These results can be explained by the fact that individuals selected for this study were symptomatic only when CLs were used. This finding means that the presence of a CL produces changes in the ocular surface that provoke those variations, even in normal situations, because the CL itself increases tear evaporation,51 masking the effect that 2 hours of exposure to CAE could have had on the ocular surface.
The modest change found in some studied variables (i.e., bulbar and limbal hyperemia) although statistically significant, seems to be of little clinical relevance. However, the small differences in humidity between CAE (22 ± 2°C, RH 19% ± 4%) and INE (24.2 ± 1.3°C, RH 34.8% ± 2.9%) environments, and the short period of exposure time (2 hours) can explain the small variations in hyperemia. It is likely that differences in the variables measured will increase with longer exposure time and/or lower humidity.
Recently, adverse environments with high rates of air flow have been used to create three models of keratoconjunctivitis sicca in mice: transdermal scopolamine patches,13 controlled low RH,14 and low RH with abnormally low-blink frequency.52 The desiccating stresses induce inflammatory responses that are implicated in the pathogenesis of DE disease.53 54 These animal models can be replicated in humans in a CAE and an EC. Because low RH provokes an increase in tear evaporation that leads to hyperosmolarity of tears,55 it may be one of the causative factors of inflammation in DE disease.56
Our CAE and INE models will permit improvement in the design of clinical trials. DE is one of the most common ocular problems in the general population,57 but there is a lack of international consensus on diagnosis criteria or clinical test end points.58 The standardization of CAE and EC conditions will help to produce repeatable outcomes in both clinical and research applications. It will also help to define test end points and to evaluate new diagnostic technologies or therapies.1
In conclusion, the present study demonstrated that adverse environmental conditions can alter a normal-to-borderline ocular surface. The wearing of CLs has a similar impact on the ocular surface in the CAE as in the INE, and alterations induced by these environments are reversed after 1 week. Therefore, the conditions recreated in this study can be of further use to standardize ocular surface status in the evaluation of DE diagnostic end points and/or to test new therapies.
| Acknowledgements |
|---|
| Footnotes |
|---|
Supported by Grant FEDER-CICYT: MAT2004-03484-CO2-02, Ministry of Education, Spain.
Submitted for publication July 17, 2006; revised December 22, 2006, and May 7, 2007; accepted June 18, 2007.
Disclosure: M.J. González-García, None; A. González-Sáiz, None; B. de la Fuente None; A. Morilla-Grasa, None; A. Mayo Iscar, None; J. San-José, None; J. Feijó, None; M.E. Stern, Allergan, Inc. (E); M. Calonge Allergan, Inc. (C)
The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C.
1734 solely to indicate this fact.
Corresponding author: María J. González-García, IOBA-University of Valladolid, Ramón y Cajal 7, Valladolid E-47005, Spain; aluche{at}ioba.med.uva.es.
| References |
|---|
|
|
|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |